期刊文献+

Feasibility of Using lohexol Instead of Meglumine Diatrizoate to Do a Test of Sensitivity to Iodum

Feasibility of Using lohexol Instead of Meglumine Diatrizoate to Do a Test of Sensitivity to Iodum
下载PDF
导出
摘要 BACKGROUND:Coronary angiogram and percutaneous coronaryangioplasty are becoming important techniques to make diagnosisand relieve symptoms for the patients with CAD.But higherincidence of hypersensitivity when meglumine diatrizoateas as a agent todo iodum sensitivity test will make some difficuties in practice of CAGand PTCA.PURPOSE:Using iohexol instead of meglumine diatrizoateas a agent to take sensitivity test may be helpful to promote theprevalance the CAG and PTCA in clinical.METHODS ANDPATIENTS:850 patients were enrolled into this study.Patients withpositive reaction when meglumine diatrizoate as a agent to do sensitivitytest accepted the second test using Iohexol.RESULTS:21 Patientaccepted the second test in this study,of the patients,only 1 patient had asame complaints during the 1st and 2nd test.then was rejected to give herCAG and PTCA procedures.The others with positive reaction during 1sttest showed negative reaction during 2nd test,then accepted CAG andPTCA procedure.All the 20 patients underwent CAG and PTCA had noallergic reaction during the procedure.CONCLUSION:Using iohexolinstead of meglumine diatrizoate as a agent to do iodum-sensitivity testmay be helpful to reduce incidence of the false hypersensitive to iodumand promote the practice of CAG and PTCA in clinical. BACKGROUND:Coronary angiogram and percutaneous coronary angioplasty are becoming important techniques to make diagnosis and relieve symptoms for the patients with CAD.But higher incidence of hypersensitivity when meglumine diatrizoateas as a agent to do iodum sensitivity test will make some difficuties in practice of CAG and PTCA.PURPOSE:Using iohexol instead of meglumine diatrizoate as a agent to take sensitivity test may be helpful to promote the prevalance the CAG and PTCA in clinical.METHODS AND PATIENTS:850 patients were enrolled into this study.Patients with positive reaction when meglumine diatrizoate as a agent to do sensitivity test accepted the second test using Iohexol.RESULTS:21 Patient accepted the second test in this study,of the patients,only 1 patient had a same complaints during the 1st and 2nd test.then was rejected to give her CAG and PTCA procedures.The others with positive reaction during 1st test showed negative reaction during 2nd test,then accepted CAG and PTCA procedure.All the 20 patients underwent CAG and PTCA had no allergic reaction during the procedure.CONCLUSION:Using iohexol instead of meglumine diatrizoate as a agent to do iodum-sensitivity test may be helpful to reduce incidence of the false hypersensitive to iodum and promote the practice of CAG and PTCA in clinical.
出处 《中国介入心脏病学杂志》 1998年第4期192-192,共1页 Chinese Journal of Interventional Cardiology
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部