摘要
根据相似理论,对50t电铅熔炉进行了冷态模拟试验,其结果表明:炉内气流分布不均匀、炉子内部结构不尽合理、工艺及热工操作制度尚欠完善。为此,提出了相应的改进措施。
Based on similarity theory,simlated cold test for 50 t electroltic lead smelter was made. The test resucts shown that the furnace's construction was unreasonable.process and thermal operating system were imperfect,internal gas flow was uneven distribution, therefore, improving measure for the farnace were obtained in this paper.
出处
《湖南有色金属》
CAS
1998年第1期41-44,共4页
Hunan Nonferrous Metals
关键词
电铅溶炉
模拟试验
节能
Electrolytic lead smelter Simulated test Energy saving