摘要
以贵州玉屏县贺家滩水电站在试运行中发生的一起反水锤抬机事故为例,对反水锤现象进行了原因分析,并提出了防范措施。
Taken the example of a raising-turbine accident resulting from reversion water hammer happened in operation of Hejiatan Hydropower Station, Yuping County, Guizhou Province, the causes of phenomenon of reversion water hammer is analyzed and some Precautionary measures are presented in this paper.
出处
《贵州水力发电》
1998年第2期36-37,共2页
Guizhou Water Power
关键词
反水锤抬机
原因
防范措施
raising-turbine resulting from reversion water hammer, analysis, precationary measure