本文通过对用热风作干燥剂的储仓式制粉系统的热力计算及干燥剂组成成分的确定,分析了制粉系统在不同的运行工况下,保证最佳磨煤通风量时,干燥剂份额配比的优化选择,并对现场运行应注意的问题提出了建议。
Authors carried out the thermodynamic process calculation of bin - and - feeder system with the heat wind as siccative and define the siccative' s conponent, the optimum distribution if the siccative's component under the various conditions with the optimal coal pulverizing wind flux, and further, provided several suggestions about the problems that should be paid attention to in site.