期刊文献+

Implicit characteristic parameter of a programmed temperature retention index database

Implicit characteristic parameter of a programmed temperature retention index database
原文传递
导出
摘要 In a programmed temperature retention index (PTRI) database, there exists a characteristic parameter rt0/β that can be calculated if the experimental parameters are clearly given. This characteristic parameter can be used to flexibly reproduce the original PTRI data under chromatographic conditions different from those originally given. As this characteristic parameter is not explicitly given, it is suggested to name this parameter as the implicit characteristic parameter (TCP) of a PTRI database. The ICP in White’s PTRI database was easily found and used satisfactorily to reproduce PTRI of some test compounds using either a Hewlett-Packard ultra-performance OV-1 column or a self-coated OV-1 column. The reproduction of PTRI could not be realized on columns of different materials. The fact that several PTRI databases measured on glass capillary columns could not satisfactorily be reproduced on fused silica column is explained. In a programmed temperature retention index (PTRI) database, there exists a characteristic parameter rt0/β that can be calculated if the experimental parameters are clearly given. This characteristic parameter can be used to flexibly reproduce the original PTRI data under chromatographic conditions different from those originally given. As this characteristic parameter is not explicitly given, it is suggested to name this parameter as the implicit characteristic parameter (TCP) of a PTRI database. The ICP in White's PTRI database was easily found and used satisfactorily to reproduce PTRI of some test compounds using either a Hewlett-Packard ultra-performance OV-1 column or a self-coated OV-1 column. The reproduction of PTRI could not be realized on columns of different materials. The fact that several PTRI databases measured on glass capillary columns could not satisfactorily be reproduced on fused silica column is explained.
出处 《Science China Chemistry》 SCIE EI CAS 1996年第3期308-317,共10页 中国科学(化学英文版)
基金 Project supported by the National Natural Science Foundation of China
关键词 programmed TEMPERATURE gas CHROMATOGRAPHY programmed TEMPERATURE RETENTION index database REPRODUCIBILITY influence af COLUMN materials. programmed temperature gas chromatography, programmed temperature retention index, database, reproducibility, influence af column materials.
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部