期刊文献+

血小板三种测定方法实验比较

THE COMP ARISON OF THREE METHODS OF PLATELET DETERMINATION
下载PDF
导出
摘要 本文对血小板三种测定方法——直接计数法、血涂片计数法和自动化仪器(东亚F—800型血球计数仪)分析法作了方法比较实验研究。结果表明:自动化分析法准确度好、精密度高,直接计数法次之,与自动化法比较,其相关系数为0.9214,回归方程Y=0.8867X+6.1528;血涂片法误差较大,与自动化法比较P<0.01,具有显著性差异。故本文认为血涂片法的推广应用尚有一定的局限性。 Three methods of platelet determination-direct count method,smear count method andautomated method(Sysmex F-800 micro-cellcounter) were compared in the paper.The re-sults indicated that automated method was the best inaccuracy and precision.Comparedwith automated method,coefficient of corelation of direct method was. 9214,Y=0. 8867x+6.1528. The results of comparison of smear method and automated method showed signifi-cant difference(P<0.01 ).Therefore,the paper suggested that clinical application of smearmethod has certain limitatio
出处 《川北医学院学报》 CAS 1995年第4期6-7,共2页 Journal of North Sichuan Medical College
关键词 血小板 血涂片法 直接计数法 自动化法 Platelet Smear method Direct count method Automated method
  • 相关文献

参考文献1

  • 1李树萍.血涂片计数血小板方法介绍与直接计数方法的比较[J]临床血液学杂志,1992(04).