填埋场监测系统包括地下水监测,地下水排水系统水位监测,沥滤液水位监测,沥滤液贮水池监测,渗漏液监测,气体监测,土壤监测和最终覆盖层的稳定性监测8个部分.文中分别叙述了地下水监测的取样点的布设,监测井的设计与取样频率,地下水排水系统水位监测的监测井的设计与取样频率,沥滤液水位监测的监测井的设计,沥滤液贮水池监测的监测频率和监测因子,渗漏液监测的监测器,气体监测的探测管的设计及安装,土壤监测的布点采样以及对最终覆盖层稳定性监测的监测方法.
Landfill monitoring system includes monitorings of underground water, water level of underground water drainage system, Leachate level, leachate storage tank, leachate, gases, soil and stabilization of final cover layer eight parts. The article separately intron-duced underground water sampling area, design and sampling frequency of the monitoring wells, design of monitor wells and sample frequency for water level monitoring of the underground water drainage system, monitor wells design for monitoring leachate level, monitoring frequency and monitor factor for monitoring of leachat stroage tank, leachate monitoring,soil sampling and monitoring methods on stabilization monitoring of final cover materials.