摘要
分析了沈阳鼓风机厂产品DH80—15 型空压机联轴器因过盈配合不当而造成联接失效的原因.通过详细的计算及校验,重新选择了过盈配合尺寸,解决了打滑联接失效的问题.
This contribution analyzes reasons of connection failure of a coupling in DH80-15 ait compressor was made in Shenyang Blowing Machine Plant. Based on de- tail calculation and inspection interference fit sizes were selected again. Therefore, the prob- lem of connection slip had been solved.
出处
《冶金动力》
1995年第5期35-37,共3页
Metallurgical Power
关键词
联轴器
过盈配合
校验
强度
Coupling, Interference fit, Inspection, Strength