摘要
本文在非正统三相不平衡电路的瞬时无功功率理论下,得到Y0/△-11接线牵引变电所的无功电流和无功功率各瞬时分量,并提出了合理的补偿方法.
The instantaneous of reactive current and reactive power in the Y0/△-11traction substation are proposed on the basis of the theory of instantaneousreactive power in three-phase systems under nonsinusoidal,unbalanced situations,and the method of their compensation is discussed.
出处
《铁道科学与工程学报》
CAS
CSCD
1995年第2期31-37,共7页
Journal of Railway Science and Engineering
关键词
牵引变电所.无功瞬时分量
补偿
traction substation, instantaneous reactive power, compensation