期刊文献+

Bulk acoustic wave Barker code sequence and the application in ultrasonic NDT 被引量:2

Bulk acoustic wave Barker code sequence and the application in ultrasonic NDT
原文传递
导出
摘要 A simple and convcnient method to gain bulk acoustic wave Barker code sequence is presented and the results of the correlation are givcn. The transducer response to a unit electric pulse is used as a unit code constituting the Barker code sequence of acoustic signal. The phase precision of the code sequence as well as the fairly ideal response function are guaranteed by the high accuraey of a DATA-2020 Arbitrary Waveform Synthesizer and a DATA-6000 Universal Wavcform Analyzer. Some deviations between the experiments and thcory are caused by the transient response and timc delay characteristics of the ultrasonic tansducer. A simple and convcnient method to gain bulk acoustic wave Barker code sequence is presented and the results of the correlation are givcn. The transducer response to a unit electric pulse is used as a unit code constituting the Barker code sequence of acoustic signal. The phase precision of the code sequence as well as the fairly ideal response function are guaranteed by the high accuraey of a DATA-2020 Arbitrary Waveform Synthesizer and a DATA-6000 Universal Wavcform Analyzer. Some deviations between the experiments and thcory are caused by the transient response and timc delay characteristics of the ultrasonic tansducer.
出处 《Chinese Journal of Acoustics》 1994年第3期219-223,共5页 声学学报(英文版)
关键词 Barker code CORRELATION Ultrasonic NDT Barker code, Correlation, Ultrasonic NDT
  • 相关文献

同被引文献10

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;