COMPARISON OF THE DUPLICATOR'S CARDIAC CYCLE WITH THAT OF HUMAN LEFT HEART CIRCULATION WHEN AORTIC VALVE ALLOGRAFT TESTED
COMPARISON OF THE DUPLICATOR'S CARDIAC CYCLE WITH THAT OF HUMAN LEFT HEART CIRCULATION WHEN AORTIC VALVE ALLOGRAFT TESTED
摘要
By adjusting the testing condition,we obtained the best pulse hydrodynamic per-formance of aortic valve allograft tested in the duplicator made by Chengdu Universi-ty of Science and Technology.Meanwhile,we regarded the condition of the duplicatoras the consilience of human left circulation.By comparing the results(comparison)ofthe different periods of the cardiac cycle including beat to beat interval(RR),systolictime(ST),left ventricular eject time(LVET)and the relationship between them,which got from the observation on volunteers with normal or prostheses aortic valveby using two dimensional Doppler echocardiography,with that of the testing condi-
-
1Xuejun Wu Qiang Chang Yiru Guo Jianhua Guo Jiaqiang Guo Jihai wang Xiaodong Zhu Cardiovascular Institute and Fu Wai Hospital,Chinese Academy of Medical Sciences,Beijing 100037,China.COMPARISON OF ALLOGRAFT AORTIC VALVE ORIFICE AREA ESTIMATED BY GORLIN FORMULA AND THE CONTINUITY EQUATION IN A PULSATILE DUPLICATOR[J].Chinese Journal of Biomedical Engineering(English Edition),1993,2(3):126-126.
-
2CHU Yin ping 1,CHEN Ru kun 2,FAN Yu bo 3 , PU Fang 31 Department of Thoracic & Cardiovascular Surgery Second Hospital Affiliated Shanxi Medical University, Taiyuan 030001,China 2 Second Affiliated Hospital of Zhejiang University Medical.Hydrodynamics of a Newly China-Made Jiuling Bileaflet Heart Valve Prostheses[J].Chinese Journal of Biomedical Engineering(English Edition),2000,9(4):168-179. 被引量:8
-
3Lu Songfang,Yang Zibin,Peng Yi,Dai Weihan,Yu Xiaojun,Zhu Anping(Institute of Basic Medical Sciences, CAMS,Beijing, 100005,China)Wang Jihai,Zhu Xiaodong,Li Xiaodong,Di Yunxi(Fu Wai Hospital, CAMS,Beijing, 100037,China).A NEWLY DUPLICATOR FOR PULSATILE AND STEADY FLOW TESTING OF ARTIFICIAL HEART VALVE[J].Chinese Journal of Biomedical Engineering(English Edition),1996,5(2):79-85.
-
4Artificial Organs[J].Chinese Journal of Biomedical Engineering(English Edition),1993,2(2):51-52.
-
5Hemodynamic and Biomechanics[J].Chinese Journal of Biomedical Engineering(English Edition),1993,2(2):57-58.
-
6韩耀坤,杜文彦.骨移植的免疫学基础[J].黑龙江医药科学,2013,36(1):92-94. 被引量:1
-
7Fan Zhaohui,Huang Qingheng,Zhao Jian, Geng Xigang,Liu Jianlin,Ren Huping Department of Cardiovascular Surgery, First Affiliated Hospital of Xi′an Medical University, Xi′an 710061.EXPERIMENTAL STUDY OF INFLUENCE OF LIQUID NITROGEN PRESERVATION ON ANTIGENICITY OF HUMAN HOMOGRAFT AORTIC VALVE[J].Journal of Pharmaceutical Analysis,1999,13(2):157-161.
-
8Jian-Feng Wei,Shu-Sen Zheng the Department of Hepatobiliary Surgery, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China.NF-kB in allograft rejection[J].Hepatobiliary & Pancreatic Diseases International,2003,2(2):496-499.
-
9LIN Chang-yan 1, LI Bing-yi 1, JIANG Yi-ling 1, WANG Jing 1, YAN Dian-jia 2 ,WU Han-kun 2 , LIU Ting 2 ,SUN Yan-qing 1 1 Beijing heart lung & blood vessel disease institute-An Zhen Hospital, Beijing 100029, China 2 The Eleventh Institute of China Aerospace Industry Parent Company, Beijing 100038, China.The Characteristics of a Spiral Blood Pump[J].Chinese Journal of Biomedical Engineering(English Edition),2003,12(4):151-157.
-
10车小燕,罗爱武,黄洪莲,周明乾,张亚莉,王小宁,郭亚军.Induction of specific immunosuppression of cardiac allograft rejection withmonoclonal antibodies to CD44, LFA-1 and ICAM-1[J].Journal of Medical Colleges of PLA(China),2000,15(3):217-220.