THE RESEARCH OF THE CHARACTERISTICS OF LUNG SOUND UNDERGOING HIGH FREQUENCY JET VENTILATION
THE RESEARCH OF THE CHARACTERISTICS OF LUNG SOUND UNDERGOING HIGH FREQUENCY JET VENTILATION
摘要
High frequency jet ventilation (HFJV) is an open-system with high frequencyand lower tidal volume.The tidal volume may be significantly less than the anatomi-cal dead space of the lung,so it is difficult to apply the tidal volume to controlHFJV.In order to look for an index of quantitatively HFJV management,we studiedthe lung soundsunder going HFJV on neurosurgical patients when the driving pres-sure from 0.6 to 1.4 kPa,and found that:
-
1吕沅岡,王毅.高纯度羊促黄体生成素(oLH)的制备[J].生殖与避孕,1989,9(4):14-17.
-
2Xiqing Sun Xingyu Wu.Monitoring of CO2 Tension during High Frequency Jet Ventilation[J].Journal of US-China Medical Science,2006,3(2):45-49.
-
3YanChuanchu et al. Affiliated Hospital of Shandong Med Uni Jian 250012 Chin J Neuro Psyc 1994: 27(3):141..Quantitative Histopathologic Study and Ultrastructural Observation on Plymyositis / Dermatomyosisit.[J].Chinese Medical Journal,1995(2):63-63.
-
4黄学顺,史玉梅,刘秋如,黎日真,吴吉茂,曹勇.失血性休克失代偿后行声门外HFJV的实验研究[J].江西医学院学报,1992,32(2):101-104.
-
5Zhou Wei,Yang Jieqiu,Lin Shujuan,Li Yuejie,Wang Yuehua,Wang Qiang(Inst. of Biomedical Engineering,CAMS,Tianjin 300192,China)Sun Jialan(Tianjin First Centrol Hospital,Tianjin 300192,China).THE DESIGN AND APPLICATION OF RELAXANT MONITORING SYSTEM[J].Chinese Journal of Biomedical Engineering(English Edition),1998,7(1):19-21.
-
6陈敏,曾祥龙,吴兴裕.Correlation analysis of five factors influencing minute volume during high frequency jet ventilation on lung modal: a laboratory study[J].Journal of Medical Colleges of PLA(China),1994,9(1):47-49.
-
7张传汉,马自成,金士翱.Clinical Study of P_(ET)CO_2 in One-lung Ventilation[J].Journal of Huazhong University of Science and Technology(Medical Sciences),1996,16(3):179-182.
-
8Xuejun Wu Jianhua Guo Jihai Wang Qian Chang Yiru Gao Jiaqiang Gao Xiaodong Zhu Cardiovascular Institute and Fu Wai Hospital Chiese Academy of Medical Seienees,Beijing 100037,China.COMPARISON OF THE DUPLICATOR'S CARDIAC CYCLE WITH THAT OF HUMAN LEFT HEART CIRCULATION WHEN AORTIC VALVE ALLOGRAFT TESTED[J].Chinese Journal of Biomedical Engineering(English Edition),1993,2(3):93-93.
-
9SHI Guo-chao HUANG Shao-guang LI Min DENG Wei-wa WAN Huan-ying.Comparison of High-Frequency Oscillation Ventilation with Conventional Mandatory Ventilation in Animal ARDS Model[J].上海第二医科大学学报,2005,25(10):1091-1091.
-
10范文茹,王化祥,杨程屹,马世文.Time Series of EIT Measurements and Images During Lung Ventilation Based on Principal Component Analysis[J].Transactions of Tianjin University,2010,16(5):366-372.