摘要 本文在国内首次报道了在高分子和胶体溶液中用玻璃电极测定 pH 值时具有吸附作用,并在相同溶液中与锑电极作了对比试验。文中对玻璃电极的吸附机理做了理论上的分析,两电极的差异(△pH)是由于玻璃电极吸附所致,并将两电极用于皮革生产中,绘制了两电极的△pH 关系图。 This is a first paper in China reporting about adsorption of glass electrode in determining pH value in polymer and colloid solution,and the experiments in the same solution comparing with antimony combination electrode.The experments show that there is a significant differ- ence between pH values of polymer and colloid solution determined with glass electrode and an- timony combination electrode,because the glass electrode has an adsorpting effect to polymer and colloid.So that the author of this paper has researched on the cause and regularity of the difference of pH values in polymer and colloid solution resulting from adsorption of glass elec- trode,and also analysized theoretically the adsorpting effect of glass electrode on the base of the experiments.From the using range of glass electrode and its callibration factor when used in polymer and colloid solution have been obtained.Finally,this paper also shows usage of these two kinds of electrode in determining pH values of leather solution,and the correspond- ing relation graph of pH value determined by these two kinds of electrodes.
出处 《陕西科技大学学报(自然科学版)》 1993年第4期59-64,共6页 Journal of Shaanxi University of Science & Technology
关键词 PH 值测定 锑复合电极 玻璃电极 吸附作用 高分子和胶体溶液 determination of pH value antimony combination electrode glass electrode adsorption polymer and colloid solution
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部