摘要 本文对圆度仪国家检定规程中决定放大倍数精度的单项指标“定度误差”、“相邻放大比误差”、“任意档对于定度档的放大比误差”,及综合指标“测量系统示值误差”进行了分析计算,并阐明了综合指标与单项指标的关系。 In this paper, some indexes of the maganification accuracy, given by the National Verification Regulation of Roundness Measuring Instrumdnt, are analysed and calculated. These indexes include three individual indexes, i. e. the caliberation error, the adjacent magni- fying ratio error and the magnifying ratio error of any range refer to the caliberation range, and a composit index, the indicating error of the measuring system. And also, the relationship between the composite index and the individual indexes is detailed.
作者 邵大钟
机构地区 杭州商学院
出处 《中国计量学院学报》 1993年第1期71-73,共3页 Journal of China Jiliang University
关键词 圆度仪 定度误差 放大比 示值误差 roundness measuring instrument caliberation error maganification ratio indicated error