安居水电厂灯泡贯流式水轮发电机组的试运行

Test Operation of Bulb Tubular Turbine Generating Units at Anju Power Plant
下载PDF
导出
摘要 本文对安居水电厂2台灯泡贯流式水轮发电机组自投入试运行以来,出现的受油器壳体开裂、导叶接力器缸体和活塞拉伤、转轮桨叶传动拐臂连接销脱落、导叶外轴承座漏水、主轴工作密封漏水侵入水导轴承、锁锭装置固定螺钉剪断等故障的经过、原因分析及其处理办法进行了叙述。 The paper describes the courses , case studies and treatment methods for troubles occurred since test operation of two bulb tubular turbine generating units at Anju Power Plant. These troubles include cracking of oil catcher casing, tensile failure of servomoter cylinder and piston of guide vane,removal of driving knee coupling pin of runner paddle, seepage of external bearing seat of guide vane,water leakage from main shaft working seal into bearing of turbine guide vane,shear fracture of fixed screw for locking device.
出处 《四川水力发电》 1993年第S1期17-27,共11页 Sichuan Hydropower
关键词 灯泡贯流式机组 导叶接力器 转轮浆叶 主轴工作密封 锁锭装置 bulb tubular turbine generating units ,servomoter of guide vane,runner paddle,main shaft work-ing seal,locking device.