期刊文献+

Preparation and Application of PVC Membrane Ion-Selective Electrode in Measuring pH of the Upper Digestive Tract

Preparation and Application of PVC Membrane Ion-Selective Electrode in Measuring pH of the Upper Digestive Tract
下载PDF
导出
摘要 A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and polyvinylchloride (PVC) as a base. It was shown that the electrode has widelinearity (0.5-8, 3-12), good reproducibility, proper responsible time (【30s),longer life span (15 days). And the measurement was carried out in 50 cases bythe electrode. A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and polyvinylchloride (PVC) as a base. It was shown that the electrode has widelinearity (0.5-8, 3-12), good reproducibility, proper responsible time (<30s),longer life span (15 days). And the measurement was carried out in 50 cases bythe electrode.
出处 《中国医科大学学报》 CAS CSCD 1991年第S2期49-54,共6页 Journal of China Medical University
关键词 PVC MEMBRANE ion-pH selective ELECTRODE UPPER DIGESTIVE TRACT PVC membrane ion-pH selective electrode upper digestive tract
  • 相关文献

参考文献10

  • 1Dr U. Oesch,Dr Z. Brzózka,Ms A. Xu,W. Simon.Solvent polymeric membrane pH catheter electrode for intraluminal measurements in the upper gastrointestinal tract[J]. Medical & Biological Engineering & Computing . 1987 (4)
  • 2Rebecca B. Troxell PA-C,Sarah R. Kohn BA,Dr. James E. Gray MD,Richard W. Welch MD,Edward D. Harloe BS,Raj K. Goyal MD.A computer-assisted technique for 24-hour esophageal monitoring[J]. Digestive Diseases and Sciences . 1982 (12)
  • 3Takashi Machida M.D..A Study of intragastric ph in patients with peptic ulcer-with special reference to the clinical significance of basal pH value[J]. Gastroenterologia Japonica . 1981 (5)
  • 4Cui Hongbo,et al.Evaluation of critical parameters for measuerment of pH by flow injection analysis. Analytica Chimica Acta . 1985
  • 5M. E. Meyerhoff,et al.An ion-selective electrode/flow injoction analysis experiment. Journal of Chemical Education . 1983
  • 6Yoshizawa R,et al.Studies on the gastric function by telemetering endo-radio-capsule. JPn J Gastroenterology . 1969
  • 7Arrosa W,et al.A computer-assisted technique for long-term gastric pH monitoring. International Journal of Biomedical Computing . 1984
  • 8Takashi M A.Study of Intragastric pH in patients with peptic ulcer. Gastroenterology Japonica . 1981
  • 9Oesch O,et al.Solvent polymeric membrane pH catheter electrode for intraluminal measurement in the upper gastrointestinal tract. Medical and Biological Engineering and Computing . 1987
  • 10Edward W,et al.The determination of gastric acidity by the glass electrode. Gastroenterology . 1965

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部