摘要
中央电视塔属于特殊超高层建筑物,一旦发生火灾扑救难度较大,因此消防设计方面有其特殊性。本文较详细介绍,本着“预防为主,防消结合,立足自救”方针的消防设计方案。以及移动式化学灭火器,消火栓灭火系统,自动喷水灭火系统,固定式“1301”灭火系统等的保护措施。
Central TV Tower is a superhigh building of special kind To
put out the fire is rather difficult in case it takes place in such a building.
The design of fire protection in the Tower,therefore,is also a special
one.The desiga in aeeordanee with the gaiding principles of'take
precautions against fire first,integrate precautions with fighting and
stand upon self-fighting the fire'and the protective measures of movable
chemical fire extinguisher,fire hydrant extinguishing system,automatic
Water-spurting extinguishing system and fixed '1301' extinguishing system
are introduced.
出处
《广播与电视技术》
北大核心
1991年第6期19-26,共8页
Radio & TV Broadcast Engineering