摘要 1987.11~1989.10月我院共植入国产人工晶体64例74眼,有较完整随访材料的46例54眼,随访时同3.5~10个月(平均7.5个月)。术后矫正视力1.0以上33眼,占61.1%,0.5以上51眼,占94.4%。术后视力恢复满意,并发症少。术后视力的恢复结果与术前病例的选择,术后屈光不正度数以及并发症有密切的关系。 From November 1987 to October 1989, 64 cases ( 74 eyes ) of cataract operations were performed with extracapsular cataract extraction and China-made PMMA and SILICON IOL implantation. 46 cases (54 eyes) were followed up 3.5-10 months, averaging 7.5 months. Visual acuity of 1/0-1.5 was achieved in 61.1% and 0.5 or better in 94.4% of the eyes. Complications were less and the vision restored was satisfactory.