摘要 以聚苯乙烯羧基荧光微球为固相载体,将人免疫球蛋白G(IgG)和猪血红蛋白(Hb)分别与微球偶联,应用Luminex-100TM荧光微球检测系统检测抗体IgG和抗原Hb与荧光微球的偶联效率。结果表明,采用100μg.mL-1抗体或抗原浓度可以获得较高的偶联效率,且检测快速灵敏。应用荧光微球进行抗原抗体免疫检测可行。 Human immunoglobin G(IgG) and swine hemoglobin(Hb) were coupled to the carboxylated polystyrene fluorescent microsphere used as solid carrier,and Luminex-100TM system was used to detect the coupling efficiency between fluorescent microsphere and IgG or Hb.Results showed that,the maximal coupling efficiency could be achieved by using 100 μg·mL-1 antibody or antigen,and the detection was fast and sensitive.It is feasible to apply fluorescent microsphere technology to immunodetection.
出处 《化学与生物工程》 CAS 2011年第11期84-86,共3页 Chemistry & Bioengineering
基金 国家自然科学基金资助项目(31000067) 西北工业大学基础科研基金资助项目(JC200921)
关键词 荧光微球 抗体 抗原 免疫检测 fluorescent microsphere antibody antigen immunodetection
  • 相关文献

参考文献12

  • 1Wood W I, Gitschier J, Lasky L A, et al. Base composition-inde- pcndem hybridization in tetramethylammonium chloride:A meth od for oIigonueleotide screening of highly complex gene libraries [J].Proc Natl Acad Sci USA, 1985,82(6) : 1585-1588.
  • 2Iannone M A, Taylor J D, Chen J, et al. Multiplexed single nucleo tide polymorphism genotyping by oligonucleotide ligation and flow cytometry[J]. Cytometry,2000,39(2) :131-140.
  • 3Seideman J,Peritt D. A novel monoclonal antibody screening me thod using the Luminex-100 microsphere system[J]. J Immunol Methods, 2002,267(2) : 165-171.
  • 4Vercammen M, Meirlaen P, Sennesael J, et al. Diagnostic accuracy of the FIDIS multiplex fluorescent microsphere immunodetection system for anti-extractable nuclear antigen(ENA) antibodies in connective tissue diseases[J]. Clin Chem Lab Med, 2007,45 ( 4 ) : 505-512.
  • 5Etienne K A,Kano R,Balajee S A. Development and validation of a microsphere-based Luminex assay for rapid identification of clin ically relevant aspergilli[J]. J Clin Microbiol, 2009,47 (4) : 1096-1100.
  • 6Schliemann C,Roesli C, Kamada H, et al. In vivo biotinylation of the vasculature in B-cell lymphoma identifies BST-2 as a target for antibody-based therapy[J].Blood, 2010,115 (3) : 736-744.
  • 7Fulton R J, McDade R L, Smith P L, et al. Advanced multiplexed analysis with the FlowMetrix system[J]. Clin Chem, 1997,43(9) : 1749-1756.
  • 8Campos C B, Paim B A, Cosso R G, et al. Method for monitoring of mitochondrial cytochrome C release during cell death: Immuno detection of cytochrome C by flow cytometry after selective per meahilization of the plasma membrane[J]. Cytometry A, 2006,69 (6):515 523.
  • 9Brockman A, Singlam S, Phiaphun L, et al. Field evaluation of a novel eolorimetric method Double-site enzyme linked lactate dehydrogenase immunodetection assay-to determine drug suscep tibilities of Plasmodium falciparum clinical isolates from north western Thailand [J].Antimicrob Agents Chemother, 2004, 48 (4) : 1426-1429.
  • 10Zhong L, Zhang W, Zer C, et al. Protein microarray: Sensitive and effective immunodetection for drug residues[J]. BMC Biotechn ol,2010,10(1) :12.

二级参考文献27

  • 1李宇红,樊明文.壳聚糖与疫苗的黏膜递呈[J].国外医学(口腔医学分册),2004,31(5):356-358. 被引量:1
  • 2徐宜为.免疫检测技术[M].科学出版社,1991.158-182.
  • 3Evans TJ.Bioassay for tumor necrosis factor-alpha and beta.Mol Biotechnol,2000;15(3)∶243
  • 4Carins CB,Panacek EA,Harken AH,et al.Bench to bedside:tumor necrosis factor-alpha:from inflammation to resusci-tation.Acad Emerg Med,2000;7(8)∶930
  • 5Bellomo R,Kellum JA,Gandhi CR et al.The effect of intensive plasma water exchange byhemofiltration on hemodynamics and soluble mediators in canine endotoxemia.Am J Respir Crit Care Med,2000;161(5)∶1429
  • 6Lonnemann G,Floege J,Kliem V,et al.Extended daily veno-venous high-flux haemodialysis in patients with acute renal failure and multiple organ dysfunction syndrome using a single path batch dialysis system.Nephrol Dial Transplant,2000;15∶1189
  • 7Coombes AGA,Breeze V,Lin W,et al.Laefic acid-established albumin for microsphere formulation and biomedical coating.Biomaerials,2001;22(1)∶1
  • 8Yang CY,Tsay SY,Tsiang RC.Encapsulating aspirin into a surfactant-free ethyl cellular microsphere using non-toxic solvents by emulsion solvent-evaporation technique.J Microencapsul,2001;18(2)∶223
  • 9Gorbet MB,Sefton MV.Leukocyte activation and leukocyte procoagulant activities after blood contact with polystyrene and polyethylene glycol-immobilized polystyrene beads.J Lab Clim Med,2001;137(5)∶345
  • 10Satok,Tokeshi M,Kimura H,et al.Determination of coreinoembryonic antigen in human scar by integrated bead-bed immunoassay in a microchip for cancer diagnosis.Anal Chem,2001;73(6)∶1213

共引文献8

同被引文献31

  • 1葛萃萃,钟青萍,张旺,欧阳鑫.双抗夹心ELISA检测食品中大肠杆菌O157:H7方法研究[J].食品科学,2007,28(1):171-175. 被引量:31
  • 2KARMALI M A, PETRIC M, LIM C, et al. The association between idiopathic hemolytic uremic syndrome and infection by verotoxin- producing Escherichia coli[J]. Infectious Diseases, 1985, 151(5): 775-782.
  • 3ONY J, ZHE L, ROBINS B R, et al. Prevalence of verocytotoxigenic Eshcherichia coli serotype O157:H7 in children with diarrhoea attendinga sydney hospital[J]. J Paediatr Child Health, 1993, 29(3): 185-187.
  • 4YANG Hua, LI Huaping, JIANG Xiuping. Detection of foodborne pathogens using bioconjugated nanomaterials[J]. Microfluid Nanofluid, 2008, 5: 571-583.
  • 5BABACA N, GUO Yancheng, WANG Xiliang, et al. Development and application of lateral flow test strip technology for detection of infectious agents and chemical contaminants: a review[J]. Anal Bioanal Chem, 2010, 39"/: 1113-1135.
  • 6HE Xiaoxiao, ZHOU Lixia, HE Dinggeng, et al. Rapid and ultrasensitive E.coli O157:H7 quantitation by combination of ligandmagnetic nanoparticles enrichment with fluorescent nanoparticles based two-color flow cytometry[J]. Analyst, 2011, 136: 4183-4191.
  • 7QI Hui, ZHONG Zhen, ZHOU Hanxin, et al. A rapid and highly sensitive protocol for the detection ofEscherichia coli O157:H7 based on immunochromatography assay combined with the enrichment technique of immunomagnetic nanoparticles[J]. International Journal of Nanomedicine, 2011, 6: 3033-3039.
  • 8WEAGANT S D, JINNEMAN K C, YOSHITOMI K J, et al. Optimization and evaluation of a modi fled enrichment procedure combined with immunomagnetic separation for detection of E.coli O157:1-17 from artificially contaminated alfalfa sprouts[J]. International Journal of Food Microbiology, 2011, 149(3): 209-217.
  • 9WANG Lin, ZHAO Wenjun, DONOGHUE M, et al. Fluorescent nanoparticles for multiplexed bacteria monitoring[J]. Bioconjugate Chem, 2007, 18(2): 297-301.
  • 10PATHAK S, DAVIDSON M C, SILVA G A. Characterization of the functional binding properties of antibody conjugated quantum dots[J]. Nano Letters, 2007, 7(7): 1839-1845.