摘要 掺杂吸附剂可降低建材VOC的散发速率,但吸附剂在建材中的位置优化尚未见报道。本文利用多层建材VOC散发的传质模型,提出了一种优化吸附剂在建材中掺杂位置的方法。文中算例结果显示,较优的掺杂方式是将吸附剂全部置于建材的顶层,其VOC散发的峰值浓度比均匀掺杂方式下降了约70%。这为设计低散发建材提供了指导。 Doping adsorbents there is no report about position can reduce VOC enfission rate from building materials, however, optimization of adsorbents in building materials. In this paper, by applying the mass transfer model for VOC emissions from multi-layered building materials, a method is proposed to optimize the doping position of adsorbents. From the case study, it is found that the optimum doping mode is placing the overall adsorbents into the top layer of building materials, whose VOC peak concentration decreases by about 70% comparing with that in uniform doping mode. This study provides guidance on designing low-emitting building materials.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2011年第12期2100-2102,共3页 Journal of Engineering Thermophysics
基金 国家杰出青年科学基金项目(No.50725620) "十一五"国家科技支撑计划项目(No.2006BAJ02A08) 北京市科委项目(No.D09050603750802)
关键词 室内空气品质 挥发性有机化合物 传质模型 吸附剂 位置优化 indoor air quality VOCs mass transfer model adsorbent position optimization
  • 相关文献

参考文献1

二级参考文献7

  • 1WHO. International Agency for Research on Cancer [M]. Press Release No.153, 2004.
  • 2XIONG Jianyin, ZHANG Yinping, HE Zhongkai, et al. Effect of Additive Adsorption Fibers within Building Materials on VOC Emission Characteristics [C]// Proceedings of Indoor Air 2008. Copenhagen Denmark, 2008: 17-22.
  • 3JORGENSEN R B, Bjorseth O, Malvik B. Chamber Testing of Adsorption of Volatile Organic Compounds (VOCs) on Material Surfaces [J]. Indoor Air, 1999, 9:2-9.
  • 4ZHANG Jianshun, CHEN Qinyan. Modeling VOC Sorption of Building Materials and its Impact on Indoor Air Quality [R]. ASHRAE RP-1097, 2001.
  • 5RONG Haiqin, RYU Zhenyu, ZHENG Jingtang, et al. Effect of Air Oxidation of Rayon-Based Activated Carbon Fibers on the Adsorption Behavior for Formaldehyde [J]. Carbon, 2002, 40:2291-2300.
  • 6SPENGLER J D, SAMET J M, MCCARTHY J F. Indoor Air Quality Handbook [M]. New York: McGraw-Hill Companies, Inc. 2001.
  • 7WANG Xinke. Study on Prediction, Measurement and Control of VOC Emission from Building Materials [D]. Beijing: Tsinghua University, 2007.

共引文献4

同被引文献38

  • 1周定国.国外人造板甲醛散发研究现状[J].世界林业研究,1995,8(5):9-17. 被引量:23
  • 2章骅,周述琼,但德忠.室内污染控制技术研究进展[J].中国测试技术,2005,31(6):130-135. 被引量:25
  • 3黄文胜,罗清海,汤广发,唐海兵.建筑通风的历史与未来[J].建筑热能通风空调,2006,25(2):28-33. 被引量:6
  • 4汤进华,梁晓怿,龙东辉,刘小军,凌立成.活性炭孔结构和表面官能团对吸附甲醛性能影响[J].炭素技术,2007,26(3):21-25. 被引量:42
  • 5Weschler C. J. Changes in indoor pollutants since the1950s. Atmospheric Environment, 2009, 43 ( 1 ) : 153-169.
  • 6Zhang Jiefeng, Bai Zhipeng, Chang V. W. C. , et al. Bal- ancing BEC and IAQ in civil buildings during rapid urbani- zation in China: Regulation, interplay and collaboration. Energy Policy, 2011, 39(10): 5778-5790.
  • 7Auvinen J. , Wirtanen L. The influence of photocatalytic interior paints on indoor air quality. Atmospheric Environ- ment, 2008, 42(18) : 4101-4112.
  • 8Chen Wenhao, Zhang J. S. UV-PCO device for indoor VOCs removal: Investigation on multiple compounds effect. Building and Environment, 2008, 43 (3) : 246-252.
  • 9Lu Yuanwei, Wang Dinghui, Ma Chongfang, et al. The effect of activated carbon adsorption on the photoeatalytic removal of formaldehyde. Building and Environment, 2010, 45(3) : 615-621.
  • 10Zhong Lexuan, Haghighat F. , Blondeau P. , et al. Model- ing and physical interpretation of photoeatalytie oxidation efficiency in indoor air applications. Building and Environ- ment, 2010, 45(12) : 2689-2697.

引证文献3