期刊文献+

透析用水中残余氯的测定 被引量:6

下载PDF
导出
摘要 血液透析用水的质量直接影响患者的透析安全和生存质量。透析用水中残余氯超标会损害反渗膜并引起溶血性贫血。本文对透析用水中残余氯的来源、危害、控制标准和常用的检测方法作一综述,希望能为各透析中心改进透析用水检测方法提供更多依据。
出处 《中国血液净化》 2011年第11期630-633,共4页 Chinese Journal of Blood Purification
  • 相关文献

参考文献22

  • 1左力.透析用水和患者安全[J].中国血液净化,2009,8(1):1-4. 被引量:18
  • 2顾军农,张春雷,王丹,罗亮,杨胜武.预处理技术在北京自来水厂的应用与分析[J].中国给水排水,2006,22(z1):202-206. 被引量:3
  • 3Stuart W. Krasner. The formation and control of emerging disinfection by-products of health concern[J].Philos Trans- act A Math Phys Eng Sci. 2009, 367(1904):4077-4095.
  • 4中华人民共和国卫生部,中国国家标准化管理委员会.生活饮用水卫生标准[M].北京:中国标准出版社,2007,4.
  • 5Thomas W. Stief. The physiology and pharmacology of singlet oxygen[J]. Medical Hypotheses, 2003, 60:567-572.
  • 6Junglee NA, Rahman SU, Wild M, et al. When pure is not so pure:chloramine-related hemolytic anemia in home hamodi- alysis patients[J]. Hemodialy Int, 2010,14:327-332.
  • 7Tipple MA, Shusterman N, Bland LA, et a:L. Illness in hemodialysis paitents after exposured to chloramines contaminated dialysate[J]. ASAIO Trans, 1991, 37:588-591.
  • 8Fiuck S, McKane W, Cairns T, et al. Chloramine-induced haemolysis presenting as erythropoietin resistance[J]. Nephrol DiM Transplant. 1999, 14:1687-1691.
  • 9de Oliveira RM, de los Santos CA, Antoneillo i, et al. Warning: an anemia outbreak due to chloramines exposure in a clean hemodialysis unit-an issue to be revisited[J]. Ren Fail. 2009,31:81-83.
  • 10Calderaro RV, Heller L. Outbreak of hemolytic reactions associated with chlorine and chloramines residuals in he- modialysis water[J]. Rev Saude Publica, 2001,35:481-486.

二级参考文献9

  • 1[1]刘文君.微污染源水饮用水处理[M].北京:中国建筑工业出版社,1999.
  • 2.消毒技术规范[S].[S].中华人民共和国卫生部,2002,11..
  • 3国家环保局.水和废水监测分析方法[M](第4版)[M].北京:中国环境科学出版社,2002.489-490.
  • 4医疗机构污水排放要求[S].中华人民共和国国家标准GB18466-2001.
  • 5Smith GD,,Winney RJ,McLean A,Robson JS.Aluminium-related osteomalacia:response to reverse osmosis water treatment[].Kidney International.1987
  • 6Burwen DR,Olsen SM,Bland LA,Arduino MJ,Reid MH,Jarvis WR.Epidemic aluminum intoxication in hemodialysis patients traced to use of an aluminum pump[].Kidney International.1995
  • 7Kitching AR,Ritchie D,Wong JK,May A,Hatfield PJ.Chloramine-induced hemolysis associated with neurological symptoms in a home hemodialysis patient[].Clinical Nephrology.2001
  • 8Bia MJ,Cooper K,Schnall S et al.Aluminum induced anemia: Pathogenesis and treatment in patients on chronic hemodialysis[].Kidney International.1989
  • 9van der,Linde,K.,Lim,B.,Rondeel,J.,Antonissen,L.,de,Jong,G.Improved bacteriological surveillance of haemodialysis fluids: a comparison between Tryptic soy agar and Reasoner’s 2A media[].Nephrology Dialysis Transplantation.1999

共引文献22