期刊文献+

工作场所空气中双酚A的高效液相色谱测定法 被引量:2

Detecting the concentrations of bisphenol A (BPA) in air of workplaces with HPLC
原文传递
导出
摘要 目的建立工作场所空气中双酚A(BPA)的高效液相色谱测定方法。方法通过玻璃纤维滤纸采集空气中气溶胶态的双酚A,乙腈洗脱后,高效液相色谱一荧光检测器测定。结果该方法在0.01-10.00μg/ml范围中呈线性关系,检出限为0.005μg/ml,最低检出浓度为3.3-10^-5mg/m3(以采集300L空气样品计),平均加标回收率为97.5%~107.0%,相对标准偏差为2.5%.5.5%,洗脱效率为95.0%-101.9%,采样效率为99.6%,样品在室温下至少可保存7d。结论方法各项指标均符合GBZ/T210.4—2008《工作场所空气中化学物质测定方法》的要求,适用于工作场所空气中双酚A的检测。 Objective To establish the method of detecting the concentrations of bisphenol A (BPA) in air of workplaces with high performance liquid chromatographic (HPLC). Methods According to standards of methods for determining the chemical substances in workplace air, BPA in the air was collected by glass fiber filter,then dissolved by acetonitrile and determined by high performance liquid chromatography with FLD. Results There was a linear relationship within the range of 0.01-10.0 μg/ml, and the detection limit was 0.005μg/ml. The lowest detected concentration was 3.3×10-5 mg/m3. The relative standard deviation was 2.5- 5.5%. The dissolution efficiencies were 95.0%-101.9% and the sampling effieiencies were 99.6%. The samples in glass fiber filter membrane could be stored for 7 days at room temperature. Conclusion The present method could meet with the requirements of Guide for establishing occupational health standards-Part 4 Determination methods of air chemicals in workolace and be feasible for determination of BPA in workplace air.
出处 《中华劳动卫生职业病杂志》 CAS CSCD 北大核心 2011年第11期856-858,共3页 Chinese Journal of Industrial Hygiene and Occupational Diseases
关键词 双酚A 空气 工作场所 高效液相色谱法 Workplace air, BPA, High performance liquid chromatography
  • 相关文献

参考文献8

二级参考文献45

共引文献61

同被引文献17

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部