期刊文献+

Simulation and measurement of the resonant Schottky pickup

Simulation and measurement of the resonant Schottky pickup
原文传递
导出
摘要 A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the detector, the transient response of the detector, and MAFIA simulated and perturbation measured results of characteristics are presented in this paper. The resonant frequency of the pickup is about 243 MHz and can be slightly changed at a range of 3 MHz. The unloaded quality factor is about 1072 and the shunt impedance is 76 kΩ. The measured results of the characteristics are in agreement with the MAFIA simulations. A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the detector, the transient response of the detector, and MAFIA simulated and perturbation measured results of characteristics are presented in this paper. The resonant frequency of the pickup is about 243 MHz and can be slightly changed at a range of 3 MHz. The unloaded quality factor is about 1072 and the shunt impedance is 76 kΩ. The measured results of the characteristics are in agreement with the MAFIA simulations.
出处 《Chinese Physics C》 SCIE CAS CSCD 2011年第12期1124-1129,共6页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China(10925526,11079044)
关键词 resonant Schottky pickup Schottky signal characteristics of the eigenmode TMolo resonant Schottky pickup, Schottky signal, characteristics of the eigenmode TMolo
  • 相关文献

参考文献12

  • 1Bertulani C A. Nucl. Phys. A, 1997, 626: 187c-198c.
  • 2Litvinov Yu A et al. Acta Physica Polonica B, 2010, 41: 511 523.
  • 3Bosch F. J. Phys. B: At. Mol. Opt. Phys., 2003, 36: 585- 597.
  • 4XU H Set al. Chin. Sci. Bull, 2009, 54:4749.
  • 5Ohtsubo T et al. Phys. Rev. Lett., 2005, 95:052501.
  • 6Radon T et al. Phys. Rev. Lett., 1997, 78:4701.
  • 7Lambertson Glen R. electromagnetic detectors. In: Month M and Turner S ed. lecture notes in physics, vol.343. Berlin,Heidelberg: Springer-Verlag, 1989, 380.
  • 8GoldbergD A et al. AIP Conf. Proc., 1992, 249:537.
  • 9Duff J Le. High frequency non-ferrite cavities. In: Miles J. CERN Accelarator School on redio frequency engineering. Geneva: CERN, 2005. 50-57.
  • 10MAFIA version 4.0. CST GmbH, Germany. http://www.cst-china.cn/CST2009/product/mafia.