摘要 We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with an effective area of 80 mm× 80 mm. The detector is composed of a NaI scintillation crystal array coupled to four H8500 position sensitive photomultiplier tubes (PS-PMT). The intrinsic energy resolution of the detector is 11.5% at 140 keV on average. The planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/MBq. Additionally, the SPECT Micro Deluxe Phantom imaging was performed with a radius of rotation (ROR) of 40 mm. Using the FBP reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module. We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with an effective area of 80 mm× 80 mm. The detector is composed of a NaI scintillation crystal array coupled to four H8500 position sensitive photomultiplier tubes (PS-PMT). The intrinsic energy resolution of the detector is 11.5% at 140 keV on average. The planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/MBq. Additionally, the SPECT Micro Deluxe Phantom imaging was performed with a radius of rotation (ROR) of 40 mm. Using the FBP reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module.
出处 《Chinese Physics C》 SCIE CAS CSCD 2011年第12期1162-1165,共4页 中国物理C(英文版)
基金 Supported by Natural Science Foundation of China(10805049,10775149)
关键词 animal imaging SPECT parallel-hole collimator animal imaging, SPECT parallel-hole collimator
  • 相关文献

参考文献13

  • 1King M Aet al. Journal of Cellular Biochemistry Supplement, 2002, 39:221.
  • 2Alberto Del Cuerra et al. Nuclear Instruments and Methods in Physics Research A, 2007, 583:119.
  • 3Beekman F J et al. Journal of Nuclear Medicine, 2005, 46: 1194.
  • 4Kubo Net al. Annals of Nuclear Medicine, 2005, 19:633.
  • 5Bradley E Let al. IEEE Transactions on Nuclear Science, 2006, 53:59.
  • 6Choong W Set al. IEEE Transactions on Nuclear Science, 2005, 52:174.
  • 7SONG T Yet al. IEEE Transactions on Nuclear Science, 2003, 50:327.
  • 8Choong W S et al. IEEE Transactions on Nuclear Science, 2002, 49:2228.
  • 9Schramm Net al. IEEE Transactions on Nuclear Science, 2002, 4T: 1263.
  • 10Popov Vet al. IEEE Nuclear Science Symposium Confer ence Record, 2003, 3:2156.

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部