摘要 根据高大空间建筑特点、环境因素对火灾自动报警系统的影响,结合工程实例,对高大空间建筑中早期烟雾探测报警系统最大探测区域面积的使用率进行研究。通过分析早期烟雾探测报警系统各项设备的特性,设置位置、高度、长度等指标,对现有早期烟雾探测火灾报警系统设计及产品提出改进方案。 Based on the influence of characteristics and environmental factors of large space buildings on automatic fire alarm system, the utilization ratio of the maximum detection area of early smoke detection and alarm system in large space buildings is studied combined with engineering case. Based on the analysis on the characteristics of various equipments in early smoke detection and alarm system, various indicators are set including the location, height, and length; and improvement scheme is proposed for the design and products of early smoke detection and alarm system.
作者 周陶涛
出处 《建筑电气》 2011年第11期28-32,共5页 Building Electricity
关键词 高大空间建筑 火灾自动报警系统 早期烟雾探测 探测区域面积 空气采样探测报警器 Large space building Automatic fire alarm system Early smoke detection Detection area Air-sampling Detection alarm