摘要 从火灾事故树、不燃与可燃复合外墙火灾、水平防火隔离带的3个侧面分析了公通字[2009]46号文的科学性。从材料创新及产能两个侧面分析,我国建筑A级防火保温材料目前基本能满足市场需要,2013年将会完全满足市场需求;阐述了公通字[2009]46号文执行度。 The "Provisional Regulations on Fire Safety of External Wall Insulation Systems and Decoration",issued by Ministry of Public Security and MOHURD,is analyzed on Fault Tree Analysis(FTA),flammable and combustible compound wall of fire and horizontal fire buffer zone.With the documents of innovative materials and production capacity,Chinese A-level fire insulation building materials currently meet the basic needs of the market,and will meet the demands in 2013,explaining implementation of "Provisional Regulations on Fire Safety of External Wall Insulation Systems and Decoration".
作者 龙文志
出处 《建筑节能》 CAS 2011年第11期37-43,76,共8页 BUILDING ENERGY EFFICIENCY
关键词 事故树分析(FTA) 最小割集 复合外墙火灾 水平防火隔离带 中国建筑防火理论及实验体系 Fault Tree Analysis(FTA) minimal cut sets fire of compound wall horizontal fire buffer zone theoretical and experimental system of Chinese building fire