期刊文献+

预制槽型板平屋顶构造技术及热工性能分析

Analysis for structure and thermal performance of roof with reinforced concrete prefabricated corrugated board
下载PDF
导出
摘要 针对传统平屋顶在使用过程中经常出现的防水层老化、空鼓和裂缝等问题,在保持平屋顶使用传统材料的基础上,将屋顶的结构层设计为钢筋混凝土预制槽型板,通过对其构造做法及热工性能进行分析,探讨钢筋混凝土预制槽型板平屋顶构造技术在新农村住宅建设中的工程适用性。 Aiming at the waterproof layer aging,hollowing,deformation,cracks and other major issues existing during using of traditional fiat roof, on the basis of maintaining existing traditional materials,the structural layer of the roof is designed as reinforced concrete prefabricated corrugated board. By analyzing its structure and the thermal performance,this paper explores the adaptability of reinforced concrete prefabricated corrugated board flat roof structure technology in the new countryside construction.
出处 《新型建筑材料》 北大核心 2011年第11期76-78,共3页 New Building Materials
基金 河南省科技攻关计划项目(071150122)
关键词 传统屋顶 预制槽型板 防水层 构造 热工性能 traditional roof prefabricated corrugated board waterproof layer structure thermal performance