期刊文献+

Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography

Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography
下载PDF
导出
摘要 The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries. The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.
出处 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第30期2367-2371,共5页 中国神经再生研究(英文版)
基金 the Medical Program of Scientific & Technical Foundation in Xiamen in 2008, No. 3502Z20084028
关键词 two-dimensional phase-contrast magnetic resonance angiography blood flow three-dimensional time-of-flight phase-contrast magnetic resonance angiography internal carotid artery common carotid artery external carotid artery velocity encoding two-dimensional phase-contrast magnetic resonance angiography blood flow three-dimensional time-of-flight phase-contrast magnetic resonance angiography internal carotid artery common carotid artery external carotid artery velocity encoding
  • 相关文献

参考文献29

  • 1Lotz J,Meier C,Leppert A,et al.Cardiovascular flow measurement with phase-contrast MR imaging:basic facts and implementation.Radiographics.2002;22(3):651-671.
  • 2Hofman MB,Visser FC,van Rossum AC,et al.In vivo validation of magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels.Magn Reson Med.1995;33(6):778-784.
  • 3Alperin N,Vikingstad EM,Gomez-Anson B,et al.Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI.Magn Reson Med.1996;35(5):741-754.
  • 4Zhao M,Charbel FT,Alperin N,et al.Improved phase -contrast flow quantification by three-dimensional vessel localization.Magn Reson Imaging.2000;18(6):697-706.
  • 5Spilt A,Box FM,van der Geest RJ,et al.Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging.J Magn Reson Imaging.2002;16(1):1-5.
  • 6Buijs PC,Krabbe-Hartkamp MJ,Bakker CJ,et al.Effect of age on cerebral blood flow:measurement with ungated two -dimensional phase-contrast MR angiography in 250 adults.Radiology.1998;209(3):667-674.
  • 7Taviani V,Patterson AJ,Graves MJ,et al.Accuracy and repeatability of fourier velocity encoded M-mode and two-dimensional cine phase contrast for pulse wave velocity measurement in the descending aorta.J Magn Reson Imaging.2010;31(5):1185-1194.
  • 8Amano Y,Takagi R,Suzuki Y,et al.Three-dimensional velocity mapping of thoracic aorta and supra -aortic arteries in Takayasu arteritis.J Magn Reson Imaging.2010;31(6):1481-1485.
  • 9Van Es AC,Van der Grond J,ten Dam VH,et al.Associations between total cerebral blood flow and age related changes of the brain.PLoS ONE.2010;5(3):e9825.
  • 10Stoquart-El Sankari S,Lehmann P,Gondry-Jouet C,et al.Phase-contrast MR imaging support for the diagnosis of aqueductal stenosis.AJNR Am J Neuroradiol.2009;30(1):209-214.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部