期刊文献+

Seropositivity rates of water channel protein 4 antibodies compared between a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay in neuromyelitis optica patients 被引量:2

Seropositivity rates of water channel protein 4 antibodies compared between a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay in neuromyelitis optica patients
下载PDF
导出
摘要 A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay. The sensitivities and specificities of the two assays were similar. We further analyzed an additional 68 patients and 93 healthy controls using the enzyme-linked immunosorbent assay. A Kappa test showed good consistency between the two methods in terms of detection of anti-aquaporin-4 antibody in the se of neuromyelitis optica patients. No significant correlations were identified with onset age or disea duration, suggesting that aquaporin-4 antibody is a good marker for neuromyelitis optica. The enzyme-linked immunosorbent assay can be used for quantifying aquaporin-4 antibody concentrations and may be useful to dynamically monitor changes in the levels of aquaporin-4 antibody during disease duration. A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay. The sensitivities and specificities of the two assays were similar. We further analyzed an additional 68 patients and 93 healthy controls using the enzyme-linked immunosorbent assay. A Kappa test showed good consistency between the two methods in terms of detection of anti-aquaporin-4 antibody in the se of neuromyelitis optica patients. No significant correlations were identified with onset age or disea duration, suggesting that aquaporin-4 antibody is a good marker for neuromyelitis optica. The enzyme-linked immunosorbent assay can be used for quantifying aquaporin-4 antibody concentrations and may be useful to dynamically monitor changes in the levels of aquaporin-4 antibody during disease duration.
出处 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第32期2490-2494,共5页 中国神经再生研究(英文版)
基金 the grants from the Ministry of Sciences and Technology of China, No. 2006AA02A408, 2008ZX09312-014
关键词 neuromyelitis optica cell-based immunofluorescence assay anti-aquaporin 4 antibody enzyme-linked immunosorbent assay long and extended spinal cord lesions neural regeneration Key Words: neuromyelitis optica cell-based immunofluorescence assay anti-aquaporin 4 antibody enzyme-linked immunosorbent assay long and extended spinal cord lesions neural regeneration
  • 相关文献

参考文献35

  • 1Tu K N, Mayer J W. Thin films interdiffusion and reactions.New York:John Wiley & Sons, 1978
  • 2Thompson R D, Tsaur B Y, Tu K N. Contact reaction between Si and rare earth metals. Appl Phys Lett, 1981,38(7):535
  • 3Norde H,De Sousa Pires J,d'Heurle F, et al. The Schottkybarrier height of the contacts between some rare-earth metals (and silicides) and p-type silicon. Appl Phys Lett, 1981,38(11): 865
  • 4Tiren J, Magnusson U, Rosling M, et al. An improved silicon p-channel MESFET with a BF2 implanted thin channel and ErSi2 gate. Solid-State Electron, 1989,32(11):993
  • 5Sagnes I, Campidelli Y, Vincent G, et al. Tunable infrared photoemission sensor on Si using epitaxial ErSi2/Si heterostructures. Mater Sci Eng B, 1993,21(3):312
  • 6Travlos A, Salamouras N, Boukos N. Growth of rare earth silicides on silicon. J Phys Chem Solids, 2003,64 (1): 87
  • 7Lau S S, Psi C S, Wu C S. Surface morphology of erbium silicide. Appl Phys Lett, 1982,41(1):77
  • 8Tsamakis D, Vlachos M, Travlos A, et al. Electrical properties of crystalline Er and Dy silicide layers. Thin Solid Films, 2002,418(2) :211
  • 9Knapp J A, Picraux S T, Wu CS, et al. Kinetics and morphology of erbium silicide formation. J Appl Phys, 1985, 58(10):3747
  • 10Hong S M, Vantomme A, Wu M F. Growth and electrical characterization of GdSi1.7 epilayers formed by channeled ion beam synthesis. J Appl Phys, 2002,91(6):3664

共引文献1

同被引文献5

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部