摘要 [目的]探讨前路经枕寰枢关节螺钉的临床应用解剖学依据。[方法]取30具国人干燥枕颈部标本,测量与经枕寰枢关节螺钉内固定术相关的解剖径线及钉道参数;并以此类数据为依据,在所测量的干燥标本上模拟行经枕寰枢关节螺钉内固定术,经X线摄片检查内固定位置并测量钉道实际角度。[结果]前路经枕寰枢关节螺钉内固定的钉道在矢状面上呈后倾,在冠状面上呈外倾。左右两侧钉道角度大小差异无统计学差异,理想外倾角为(18.15±3.70)°,理想后倾角为(24.20±4.91)°,理想钉道长度为(34.45±2.9)mm;模拟行内固定验证,术后影像学及直视下检查结果显示,螺钉钉道均经过枕寰枢关节,角度均在此范围内,无穿出骨质者。[结论]采用前路经枕寰枢关节螺钉行枕颈融合内固定在解剖上是可行的。 [Objective]To explore the anatomical basis for clinical applications of occipitocervical fusion by anterior transarticular screw fixation from the axis to the occiput. [Methods]The correlated anatomic linear and the screw rajectory parameters of anterior transarticular screw fixation from the axis to the occiput were observed and measured on thirty adult human bone specimens.According to the data measured,anterior occiput-to-axis screw fixation was performed on the dry craniovertebral junction specimens.Roentgen rays were examined to study the positions of screws and to measure the angle of the screw trajectory. [Results]The occiput to axis transarticular screw trajectory was placed posteriorly tilting in sagittal plane and lateral tilting in coronary plane.The screw tip was located in the posterolateral third of the occipital condyle.There was no significant difference(P〈0.05) between leftside and rightside.The ideally placed angle of the screw was direct(18.15±3.70) °laterally in the coronal plane and(24.20±4.91) °posteriorly in the sagittal plane.The ideal length of the trajectory was(34.45±2.9) mm.Imageological examination and direct vision demonstrated that anterior occiput to axis screw fixation according the above results ensured insertion of the trajectory passing through the atlanto-occipital articulation and the atlanto-axial articulation without piercing the bones. [Conclusion]From the anatomical standpoint,the technique of anterior fixation from the atlas to the occiput is feasible.
出处 《中国矫形外科杂志》 CAS CSCD 北大核心 2011年第23期1995-1999,共5页 Orthopedic Journal of China
基金 全军医学科学研究"十一五"计划攻关课题(08G031)
关键词 解剖学 枕颈融合 前路 经关节螺钉 内固定 枕骨髁 anatomy occipitocervical fusion anterior approach transarticular screw internal fixation occipital condyle
  • 相关文献

参考文献17

  • 1Govender S, Vlok GJ,Fisher - Jeffes N,et al. Traumatic dislocation of the atlanto - occipital joint [ J ]. J Bone Joint Surg Br,2003,6:875 - 878.
  • 2Kleweno CP, Zampini JM, White AP, et al. Survival after concurrent traumatic dislocation of the atlanto - occipital and atlanto - axial joints : a case report and review of the literature [ J ] . Spine, 2008, 18:659 - 662.
  • 3Finn MA, Bishpo FS, Dailey AT. Surgical treatment of occipitocervical instability [ J]. Neurosurgery,2008 ,5 :961 -969.
  • 4Deutsch H, Haid RW Jr, Rodts GE Jr, et al. Occipitocervical fixation: long - term results[J]. Spine,2005,5:530 -535.
  • 5Heidecke V, Rainov NG, Burkert W. Occipito -cervical fusion with the cervical Cotrel -Dubousset rod system [ J ]. Acta Neurochir, 1998, 9:969 - 976.
  • 6倪斌,肖建如,陈德玉,袁文,叶晓健,贾连顺.枕颈融合Cervifix内固定术[J].中国脊柱脊髓杂志,2003,13(10):587-589. 被引量:15
  • 7Dvorak MF, Fisher C, Boyd M ,et al. Anterior occiput - to - axis screw fixation: part I: a case report, description of a new technique, and anatomical feasibility analysis [ J ]. Spine,2003,3:54 - 60.
  • 8Lu J, Ebraheim NA, Yang H,et al. Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability [ J ]. Spine, 1998,11 : 1229 - 1236.
  • 9Lee SC,Chen JF, Lee ST. Complications of fixation to the occiput -anatomical and design implications [ J ]. Neurosurgery ,2004,6:590 - 597.
  • 10Dvorak MF, Sekeramayi F, Zhu Q, et al. Anterior occiput to axis serew fixation: part Ⅱ: a biomechanical comparison with posterior fixation techniques [ J ]. Spine,2003,3 : 239 - 245.

二级参考文献27

  • 1郭翔,倪斌.颈椎生物力学模型的应力及进展[J].中国矫形外科杂志,2006,14(16):1225-1227. 被引量:6
  • 2章文杰,倪斌,王健,蒋涛,陶春生,任中武,王明飞,郭翔.前路经寰枢关节螺钉内固定行枕颈融合的解剖学研究[J].中国脊柱脊髓杂志,2006,16(9):681-684. 被引量:7
  • 3徐印坎 贾连顺 等.枕骨骨瓣翻转自体髂骨移植枕颈融合32例报告[J].中华外科杂志,1986,24(3):149-151.
  • 4饶书诚 石道原 等.枕骨颈椎融合术[J].中华外科杂志,1978,16:227-230.
  • 5Panjabi MM ,Dvorak J, Duranceau J ,et al. Three- dimensional movements of the upper cervical spine[ J ]. Spine, 1988,7:728 -720.
  • 6Uribe JS, Ramos E, Youssef AS, et al. Craniocervical fixation with occipital condyle screws: biomechanical analysis of a novel technique [J]. Spine,2010,9:931 -938.
  • 7Richter M, Cakir B, Schmidt R. Cervical pedicle screws : conventional versus computer- assisted placement of cannulated screws[ J]. Spine, 2005,30:2280 - 2287.
  • 8Papadopoulos EC, Girardi FP, Sama A, et al. Accuracy of single - time, multilevel registration in imageguided spinal surgery [J]. Spine,2005,3:263 - 267.
  • 9Easley SK, Pal S, Tomaszewski PR, et al. Finite clement - based probabilistic analysis tool for orthopaedic applications[J]. Comput Methods Programs Biomed,2007,1 : 32 - 40.
  • 10Panjabi MM. Cervical spine models for biomechanical research [J]. Spine, 1998,24 : 2684 - 2700.

共引文献24

同被引文献22

  • 1艾福志,尹庆水,王智运,夏虹,吴增晖.经口咽前路寰枢椎复位钢板内固定的外科解剖学研究[J].中华外科杂志,2004,42(21):1325-1329. 被引量:39
  • 2王胜,徐华梓,池永龙,林焱,黄其杉,毛方敏,王向阳,倪文飞.内镜下上颈椎前方咽后入路的应用解剖学研究[J].中华显微外科杂志,2007,30(6):417-420. 被引量:7
  • 3Dvorak MF, Fisher C, Boyd M. Anterior occiput-to-axis screw fixation: part I: a case report, description of a new technique, and anatomical feasibility analysis [J] . Spine, 2003, 28(3): E54-60,.
  • 4Dvorak MF, Sekeramayi F, Zhu Q. Anterior occiput to axis screw fixation: part II: a biomechanical comparison with posterior fixation techniques [J]. Spine, 2003, 28(3): 239-245.
  • 5Cai XH, Yu Y, Liu ZC. Three-dimensional finite element analysis of occipitocervical fixation using an anterior occiput-to-axis locking plate system: a pilot study [J]. Spine, 2014, 14(8): 1399-1409.
  • 6Kleweno CP, Zampini JM, White AP. Survival after concurrent traumatic dislocation of the atlanto-occipital and atlanto-axial joints: a case report and review of the literature[J]. Spine,2008,33(18):E659-662.
  • 7Sapkas G, Papadakis SA, Segkos D, et a1. Posterior instrumentation for occipitocervical fusion[J]. Open Orthop J, 2011, 5(6): 209-218.
  • 8Shen F, Chen B, Guo Q. Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery [J] . Int J Comput Assist Radiol Surg,2013, 8(2): 169-179.
  • 9Dérand P, R?nnar LE, Hirsch JM. Imaging, virtual planning, design, and production of patient-specific implants and clinical validation in craniomaxillofacial surgery [J]. Craniomaxillofac Trauma Reconstr,2012, 5(3): 137-144.
  • 10尹庆水,夏虹,权日,昌耘冰,刘晖,何帆,艾福志,汪维健.经口咽下颌骨劈开入路处理上颈椎或上、下颈椎腹侧病变[J].中国脊柱脊髓杂志,2008,18(1):41-44. 被引量:7

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部