1000MW汽轮机高压缸中分面漏汽分析及处理 被引量:1

The Analysis and Treatment of Steam Leakage for High Pressure Casing Split of a 1000 MW Turbine
原文传递
导出
摘要 在已投产的东方汽轮机厂日立技术超超临界1000MW机组中,普遍存在高压缸中分面局部漏汽问题。为此,在总结以往经验的基础上分析了产生漏汽的可能因素,制定了有针对性的施工措施,主要是正确处理中分面间隙和汽封径向间隙、调整猫爪支承销间隙、选择可靠的密封脂和规范螺栓热紧要求。这些措施经实际安装工作验证,效果良好,成功避免了漏汽现象。 The ultra-supercritical 1 000 MW units of Dongfang Turbine Co., Ltd. which have been put into production, are found to have the partial steam leakage problem in high pressure casing split. Based upon the past experiment, this paper develops some targeted construction measures, including proper handling the clearance of casing split and radial clearance of vapor lock, adjusting the clearance of the paw rest pin, adopting reliable sealing grease and thermal tightening of bolts, and so on. These measures work fine during installation process and avoid the steam leakage successfully.
出处 《电力建设》 2011年第12期114-116,共3页 Electric Power Construction
关键词 超超临界机组 高压缸中分面 漏汽 间隙 密封脂 ultra-supercritical unit high pressure casing split steam leakage clearance sealing grease
  • 相关文献

参考文献7

  • 1东方汽轮机厂.D1000A-000103ASM-2009螺栓预紧说明书[R].德阳:东方汽轮机厂,2009.
  • 2东方汽轮机厂.高温螺栓热紧伸长量与螺母旋转弧长对应表[R].德阳:东方汽轮机厂,2009.
  • 3DL/T438-2009火力发电厂金属技术监督规程[S].电力出版社,2009.
  • 4唐飞,董斌,赵敏.超超临界机组在我国的发展及应用[J].电力建设,2010,31(1):80-82. 被引量:56
  • 5东方汽轮机厂.N1000-25.0/600/600型汽轮机热力特性[R].德阳:东方汽轮机厂,2009.
  • 6江哲生,董卫国,毛国光.国产1000MW超超临界机组技术综述[J].电力建设,2007,28(8):6-13. 被引量:47
  • 7东方汽轮机厂.N1000-25.0/600/600型汽轮机主机证明书[R].德阳:东方汽轮机厂,2009.