高强度聚焦超声治疗恶性实体肿瘤 被引量:3

高强度聚焦超声治疗恶性实体肿瘤
下载PDF
导出
摘要 目的研究高强度聚焦超声(HIFU)治疗恶性实体肿瘤的有效性和安全性。方法应用FEP-BY01型高强度聚焦超声治疗118例中晚期肿瘤患者。根据患者身体状况、肿瘤特点及治疗顺应性等给予0.5~1.0kW的发射功率,治疗后进行临床受益率、近期疗效及安全性的分析。结果 118例患者中,其中CR0例(0%)、PR37例(31.4%)、SD47(39.8%)、PD23(19.5%)、近期总有效率31.4%(37/107);临床受益率为77.1%(91/118);毒副作用是轻微、可忍受的。结论术前评估患者肿瘤特征、适时调整治疗参数并联合其他治疗手段有助于提高近期疗效、减少并发症的产生。 Objective To investigate the efficacy and side effects of high intensity focused ultrasound (HIFU) in the treatment of malignant solid tumors. Methods 118 patients with advanced malignant tumors were designated as the candidates and were treated with FEP-BY01. The emission power of0.5-1 .SKW was applied to individuals according to physical conditions, tumor characteristics and compliance. Then clinical benefit response, recent curative effect and side effects were observed and analyzed. Results Of the 118 patients, complete remission (CR)was in zero (0%), partial remission(PR)was in 37(31.4%), stable disease(SD)was in 47(39.8%), and progression disease(PD)was in 23 (19.5%)The total response rate was 31.4%(37/107) .The clinical benefit response was 77.1%(91/118). The side effect is tolerable and mild. Conclusion Evaluation of physical conditions, tumor characteristics and compliance prior to HIFU as well as adjustment of the emission power parameters in therapy in combination with other subsecluent remedies contribute to the improvement of recent curative effects and the decrease of the incidence of comolications.
作者 李劲松
出处 《当代医学》 2011年第35期6-7,共2页 Contemporary Medicine
关键词 高强度聚焦超声 肿瘤 治疗 High-intensity focused ultrasound Neoplasm Therapy
  • 相关文献

参考文献9

二级参考文献19

  • 1蒋明东,白晋,王智彪,陈文直,李发琪,邹建中,于廷和,卢岷.高强度聚焦超声辐照兔腹主动脉粥样硬化血管后的病理学变化[J].临床超声医学杂志,2004,6(4):199-201. 被引量:3
  • 2徐建设.麻醉、手术和应激反应[J].国外医学(麻醉学与复苏分册),1994,15(3):129-131. 被引量:44
  • 3高强度聚焦超声肿瘤治疗系统临床应用指南(试行)[J].中华医学杂志,2005,85(12):796-797. 被引量:58
  • 4Vallancien G, Harouni M, Veillon B, et al. Focused, extracorporeal pyrotherapy: feasibility study in man[J]. Endourol, 1992, 6: 173.
  • 5Kohrmann K U, Michel M S, Steidler A, et al. Technical charcterization of an ultrasound source for noninvasive thermoablation by high-intensity focused ultrasound[J]. BJU Interational, 2002, 90, 248.
  • 6Vallancien G, Harouni M, Guillonneau B, et al. Ablation of superficial bladder tumors with focused extracorporeal pyrotherapy[J]. Urology, 1996, 47: 204.
  • 7Tobias Esch, George B. Stefano, Gregory L Fricchione,et al. Stress-related diseases - a potential role for nitric oxide [J]. Med Sci Monit, 2002,8(6):RA103-11S.
  • 8Kehlet H. Muhimodal approach to control postoperative pathophysiology and rehabilition[ J]. Br J Anesth, 1997,78 (5):606-616.
  • 9lvani G, Vaira M, Fossa S, et al. Protective efficacy of 3 anesthetic methods with reference to surgical stress in children [ J ]. Cah Anesthesiol, 1996,44 ( 4 ) : 297-302.
  • 10Amado JA, Diago MC. Delayed ACTH response to human corticotropin releasing hormone uring cardiopulmonary bypass under diazepam-high dose fentanyl anaesthesia [ J ]. Anaesthesia, 1994,49 ( 4 ) : 300-303.

共引文献77

同被引文献47

  • 1李艳,向理科,罗娟,王智彪.高强度聚焦超声治疗大鼠骨肉瘤的疗效观察[J].中国康复医学杂志,2006,21(10):874-876. 被引量:3
  • 2姜晓婷,菅喜岐.高强度聚焦超声热疗技术的发展和应用[J].国际生物医学工程杂志,2006,29(6):379-381. 被引量:5
  • 3刘丹,许哲宇,夏荣民,寿文德,钱德初.离体肝脏组织声学参量的温度特征研究[J].声学技术,2007,26(1):62-65. 被引量:6
  • 4尹格平.射频热凝固治疗子宫良性疾病的进展[J].中国实用妇科与产科杂志,2007,23(8):641-643. 被引量:40
  • 5Kennedy JE. High-intensity focused ultrasound in the treatment of solid tumors. Nat Rev Neurol, 2005, 5(4): 321-327.
  • 6Li FQ, Feng R, Zhang Q, Bai J, Wang ZB. Estimation of HIFU induced lesion in vitro: Numerical simulation and experiment. Ultrasonics, 2006, 44(12): e337-e340.
  • 7Lee KI, Choi MJ. Prediction and measurement of the size of thermal lesion induced by high intensity focused ultrasound in a tissue-mimicking phantom. Jpn J Appl Phys, 2009, 48:027003-1-027003-5.
  • 8Hallaj IM, Cleveland RO, Hynynen K. Simulations of the thermo-acoustic lens effect during focused ultrasound surgery. J Acoust Soc Am, 2001, 109(5): 2245-2253.
  • 9Qian S, Shen GF, Bai JF, Chen YZ. Modeling and simulation of HIFU induced lesion using different treatment pattern: 11th International Symposium on Therapeutic Ultrasound: American Institute of Physics, 2012:276-281.
  • 10Rove KO, Sullivan KF, Crawford ED. High-intensity focused ultrasound: Ready for primetme. Urol Clin N Am, 2010, 37(1): 23-35.

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部