摘要 Based on the adsorption of copper ions on single-walled carbon nanotubes(SWNTs) in electrolyte, Cu/SWNTs nanocomposite film was initially prepared on indium-doped tin oxide(ITO) substrate by one-step electrodeposition. This method may provide a versatile and facile pathway to fabricate other SWNTs-supported metal composite films. Electrochemical experiments revealed that the obtained Cu/SWNTs/ITO electrode offered an excellent electrocatalytic activity towards the oxidation of glucose and could be applied to the construction of non-enzymatic glucose biosensor. The linear range of the sensor was 1.0×10–6 to 6.0×10–4 mol/L and the response time was within 2 s. Particularly, its sensitivity reached as high as 1434.67 μA?L?mmol–1?cm–2, which was superior to any other non-enzymatic glucose biosensor based on copper-carbon nanotubes electrode reported previously. Based on the adsorption of copper ions on single-walled carbon nanotubes(SWNTs) in electrolyte, Cu/SWNTs nanocomposite film was initially prepared on indium-doped tin oxide(ITO) substrate by one-step electrodeposition. This method may provide a versatile and facile pathway to fabricate other SWNTs-supported metal composite films. Electrochemical experiments revealed that the obtained Cu/SWNTs/ITO electrode offered an excellent electrocatalytic activity towards the oxidation of glucose and could be applied to the construction of non-enzymatic glucose biosensor. The linear range of the sensor was 1.0×10–6 to 6.0×10–4 mol/L and the response time was within 2 s. Particularly, its sensitivity reached as high as 1434.67 μA?L?mmol–1?cm–2, which was superior to any other non-enzymatic glucose biosensor based on copper-carbon nanotubes electrode reported previously.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第6期1049-1054,共6页 高等学校化学研究(英文版)
基金 Supported by the National Natural Science Foundation of China(No.51072047)
关键词 Carbon nanotube COPPER Nanocomposite film Glucose biosensor Carbon nanotube Copper Nanocomposite film Glucose biosensor
  • 相关文献

参考文献39

  • 1D'Orazio P.,Clin.Chim.Acta,2003,334,41.
  • 2Malhotra B.D.,Chaubey A.,Sens.Actuators B,2003,91,117.
  • 3Poscia A.,Mascini M.,Moscone D.,Luzzana M.,Caramenti G.,Cremonesi P.,Valgimigli F.,Bongiovanni C.,Varalli M.,Biosen.Bioelectron.,2003,18,891.
  • 4Wang J.,Chem.Rev.,2008,108,814.
  • 5Clark L.C.,Lyons C.,Ann.NYAcad.Sci.,1962,102,29.
  • 6Updike S.J.,Hicks G.P.,Nature,1967,214,986.
  • 7Wang J.,Electroanalysis,2005,17,7.
  • 8Wang Y.T.,Yu L.,Zhu Z.Q.,Zhang J.,Zhu J.Z.,Fan C.H.,Sens.Actuators B,2009,136,332.
  • 9Xu Y.,Zhao K.,Zhang X.Y.,He P.G.,Fang Y.Z.,Chem.J.Chinese Universities,2010,31(3),672.
  • 10Tang H.,Chan J.H.,Yao S.Z.,Nie L.H.,Deng G.H.,Kuang Y.F.,Anal.Biochem.,2004,331,89.

同被引文献13

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部