摘要 用超声波提取、薄层扫描法测定止血定痛片中人参皂甙Rg1 的含量, 方法简便, 结果准确。薄层条件为: 含0-2% CMC- Na 的硅胶G 板, [ 正丁醇- 乙酸乙酯- 水(3∶2∶5)] 上层液- 甲醇(10∶1) 为展开剂( 展开缸预先用氨蒸汽饱和半小时) , 10 % 硫酸乙醇加热显色。扫描波长λs = 530nm ,λR= 700nm , 平均回收率为96-38 % , RSD 为1-05 % 。 A simple, rapid and accurate TLC scanning method for the quantitative determination of Ginsenside-Rg 1 in Zhixue Dingtong tablet has been established. The sample was extracted by ultrasonic method. The plate was coated with silica gel G added 0 2% CMC-Na. Using upper mixture [n-butanol-ethyl acetate-water (3∶2∶5)]-methanol (10∶1) as developing solvent. The plate was scanned at λ s=530nm, λ R=700nm. The average recovery was 96 38% with a RSD of 1 05%
出处 《中国药事》 CAS 1999年第6期403-404,共2页 Chinese Pharmaceutical Affairs
关键词 薄层扫描法 止血定痛片 人参皂甙RG1 TLC Zhixue Dingtong Tablet Ginsenside-Rg 1