摘要 孔道压浆材料的性能是影响孔道压浆质量的主要因素,而孔道压浆的质量直接影响到结构的安全性和耐久性。结合目前国内外孔道压浆材料的研究和使用现状,论述分析了预应力孔道压浆材料的性能要求及存在的问题。根据孔道压浆材料在系统性研究、商品化和绿色化等方面的发展分析,提出了孔道压浆材料未来的发展和研究方向。 The performance of duct grouting material is the main factor which affects the quality of duct grouting, while the quality of duct grouting directly affects the safety and durability of structures during the using ages. This article combined the current use and development situation of duct grouting material at home and abroad, discoursing and analyzing the performance requirement and problems of duct grouting material. Meanwhile, the development and research directions of duct grouting material were proposed, according to the development of grouting materials in systemic research, commodification and greening.
出处 《材料导报》 EI CAS CSCD 北大核心 2011年第23期65-68,79,共5页 Materials Reports
基金 交通部西部交通建设科技项目(2009318812069) 国家自然科学基金(50978031) 浙江交通科技项目(2007H21) 中央高校基本科研业务费专项资金(CHD2009JCJ151)
关键词 后张法 预应力混凝土 孔道压浆 post tensioning, prestressed concrete, duct grouting
  • 相关文献

参考文献30

  • 1王兰英,董树英.后张法预应力孔道压浆的研究[J].内蒙古公路与运输,2005(4):40-42. 被引量:5
  • 2黄玉娟,侯书恩,靳洪允,赵新颖,许亮.预应力孔道灌浆材料性能的影响因素[J].混凝土与水泥制品,2009(6):32-34. 被引量:17
  • 3Brantberger M, Stitle H, Erikson M. Controlling grout sp- reading in tunnel grouting-analyses and developments of the gin-method[J]. Tunnelling Underground Space Teehn,2000 (15) :343.
  • 4王红霞,王星,何廷树,李宪军.灌浆材料的发展历程及研究进展[J].混凝土,2008(10):30-33. 被引量:37
  • 5罗永会,高振国,韩永亮.预应力混凝土孔道灌浆材料技术性能的改进研究[J].铁道标准设计,2005,25(8):54-55. 被引量:8
  • 6中华人民共和国铁道部.TBT3192-2008,铁路后张法预应力混凝土梁管道压浆技术条件[S].北京:中国标准出版社,2008:3.
  • 7Florida Department of Transportation. FDOT standard spe- cifications[Z]. America: Florida Department of Transporta- tion, 2002.
  • 8ASTM C939-97. Standard test method for flow of grouts for pre-placed aggregate concrete (flow cone method) [S]. A- merica. Philadelphia, 1997.
  • 9ASTM C940-98a. Standard test method for expansion and bleeding of freshly mixed grouts for preplaced-aggregate concrete in the laboratory[S]. America:Philadelphia,1998.
  • 10PTI Committee on Grouting Specifications. Guide specifica tion for grouting of post-tensioned structures [Z]. America: Post-Tensioning Institute, 2003.

二级参考文献91

共引文献115

同被引文献136

引证文献21

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部