摘要
分析三聚氰胺装置中高压氨预热器多次发生列管及封头泄漏的原因,提出如何处理及防止类似事故发生的措施。
This paper explains the leakage reasons of high-pressured ammonia preheater row tubes and heads in melamine plant, and then proposes measures on how to handle and prevent the occurrence of similar accidents.
出处
《化工装备技术》
CAS
2011年第6期49-52,共4页
Chemical Equipment Technology
关键词
氨预热器
高压
列管
封头
泄漏
Ammonia preheater
High-pressure
Row tubes
Heads
Leakage