摘要 为研究某剧院休息厅的自然排烟效果的问题,根据建筑特征设计6个火灾场景。运用理论计算和数值模拟的方法,分别研究不同开窗位置、开窗面积以及环境风速对火灾时的热流场和烟气蔓延的影响。结果表明:不同开窗位置达到临界值的时间为顶窗>东西立面侧窗>北立面侧窗;有风条件下3.5%的开窗面积的排烟效果和无风时6%的开窗面积的排烟效果相当。结论是考虑当地环境风速,选择顶部5%和东西侧3.5%开窗方式,增强该剧院的自然排烟效果。 In order to study problem on the effect of natural smoke exhaust,6 fire scenarios according the features of theater lounge.Theoretical calculation and numerical simulation methods were applied to study the influence on thermal flow field and smoke propagation by the different location,area of windows and the environmental wind spead.Results were as follows: the time when reaching a critical valve of different position windowsshowed Ttop Teast,west Tnorth.With external winds,the natural smoke exhaust effect of 3.5% window open area was equal to 6.0% window area without wind.Considering the environmental winds,5% top window and 3.5% east-west window mode was selected to enhance the effect of natural smoke in theater lounge.
出处 《中国安全生产科学技术》 CAS 北大核心 2011年第11期24-29,共6页 Journal of Safety Science and Technology
关键词 剧院火灾 数值模拟 自然排烟 环境风 theater fire numerical simulation natural smoke exhaust environmental winds
  • 相关文献

参考文献10

  • 1杨林,王彬彬,蒋勇.基于数值模拟的室内商业街火灾烟气输运研究[J].中国安全生产科学技术,2008,4(4):51-54. 被引量:6
  • 2The Chartered Institution of Building Services Engineers Delta House. CIBSE.
  • 3S.M. Hockey and P. J. Rew, " Human Response to Thermal Radiation" Contract Research Report No. 97/ 1996, HSE books, Sudbury Suffolk, UK(1996).
  • 4D.A. Purser, Polymer International, 47, p. 1232(2000).
  • 5D.A. Purser, "Toxicity assessment of combustion products". SFPE Handbook of Fire Protection Engineering. , National Fire Protection Association, Quincy, Massachusetts, Third edition,2002:2-6.
  • 6BS DD240: 1997, Fire Safety Engineering in Buildings.
  • 7Custer R L P, MEACHAM B J. Introduction to performance-based fire safety [ M ]. Boston, MA, USA: Society of Fire Protection Engineers, 1997:96-100.
  • 8程远平,陈亮,张孟君.火灾过程中火源热释放速率模型及其实验测试方法[J].火灾科学,2002,11(2):70-74. 被引量:101
  • 9Beyler C L. Fire dynamics [ C ]. Dinenno P J. SFPE Handbook of Fire Protection Engineering. Third Edi- tion. Quincy, MA, USA : The National Fire Protection Association, 2002 : 2 -24.
  • 10DGJ08-88-2000.民用建筑防排烟技术规程[S].[S].公安部上海消防科学研究所 上海市消防局 上海:上海市,2000.6-16.

二级参考文献15

  • 1[1]ISO/CD 13388-Fire Safety Engineering. Design Fire Scenar ios and Design Fires [DB/CD]. May 1997.
  • 2[2]Walter W. Jones, Glenn P. Fomey. NIST TN 1431, A Technical Reference for CFAST: An Engineering Tool for Estimating Fire and Smoke Transport [ R]. National Institute of Standards and Technology, Building and Fire Research Labo ratory, Gaithersburg, MD 20899, March 2000:17 ~ 77.
  • 3[3]U. Schneider. Ingenieurmethoden im Baulichen Brandschutz [M]. expert-Verlag, Renningen, 2001:151 ~ 187.
  • 4[4]DIN Deusches Institut fuer Normung e.V. Baulicher Brand schutz im Industriebau [ M ]. Berlin: Kommentar zu DIN 18230. Beuth Verlag GmbH, 1999:301 ~ 336.
  • 5[5]ISO/CD 13393 Fire Safety Engineering. Subsystem 4.Detection, Activation and Suppression [ DB/CD ]. May 1997.
  • 6[6]U. Schneider. Bewertung des Abbrandverhaltens yon Stoffen und Waren[M]. Beitrag in Ingenieurmaessige Verfahren im Brandschutz (5). Koeln: VdS Schadenverhuetung. 1998:1~ 32.
  • 7[7]R. John. Rauch- und Waermeabzug bei Braenden in grossen Raeumen [J]. vfdb-Zeitschrift Forschung, Technik und Man agement im Brandschutz, 1988, 38(1): 21 ~ 25.
  • 8[8]ISO 5660-1. Fire tests Reaction to fire Rate of heat re lease from building products [S], First edition (1993).
  • 9[9]ISO 9705. Fire tests Full-scale room test for surface prod ucts [S], First edition (1993).
  • 10[10]National Institute of Standards and Technology. Building and Fire Research Laboratory [ EB/OL]. http://fire. nist. gov/ fire/fires/fires. html, 2000.

共引文献112

同被引文献19

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部