每搏输出量变异度监测非体外循环冠状动脉旁路移植术患者血容量变化的准确性 被引量:3

Accuracy of stroke volume variation in monitoring blood volume in patients undergoing off-pump coronary artery bypass grafting
原文传递
导出
摘要 目的评价每搏输出量变异度(SVV)监测非体外循环冠状动脉旁路移植术患者血容量变化的准确性。方法择期行非体外循环冠状动脉旁路移植术患者21例,性别不限,年龄44—77岁,体重43~93kg,ASA分级Ⅱ或Ⅲ级。开胸打开心包,待血液动力学稳定5min时(T1),以0.25ml·kg-1min-1的速率静脉输注6%羟乙基淀粉130/0.4氯化钠注射液7ml/kg。于T1和输注完毕后10min(T2)时记录HR、MAP、CVP、体循环血管阻力(SVR)、体循环血管阻力指数(SVRI)、SVV、每搏输出量指数(SVI)和CI,并计算变化率(AHR、AMAP、ACVP、ASVR、ASVV、ASVI和ACI)。AHR、AMAP、ACVP、ASVR、ASVV与ASVI进行Pearson相关性分析。以ASVI≥25%为扩容有效的标准,绘制HR、MAP、CVP、SVR、SVV监测血容量变化的ROC曲线,计算曲线下面积及其95%可信区间。结果与T1时比较,己时CVP、SVI、CO和CI升高,SVRI和SVV降低(P〈0.01),MAP和HR差异无统计学意义(P〉0.05)。AHR、ASVR与ASVI均呈负相关,相关系数分别为-0.737和-0.480(P〈0.05);ACVP、AMAP、ASVV与ASVI无相关性(P〉0.05)。ROC曲线分析结果显示:SVV的诊断阈值为8.8%,灵敏度为52.6%,特异度为100.0%。ROC曲线下面积及其95%可信区间为0.579(0.346—0.812)。结论SVV不能准确地监测非体外循环冠状动脉旁路移植术患者的血容量变化。 Objective To evalute the accuracy of stroke volume variation (SVV) in monitoring blood volume in patients undergoing off-pump coronary artery bypass grafting. Methods Twenty-one ASA Ⅱor Ⅲpatients of both sexes aged 44-77 yr undergoing off-pump coronary artery bypass grafting were enrolled in this study. Anesthesia was induced with midazolam, etomidate, fentanyl, rocuronium and dolicaine and maintained with target-controlled infusion of propofol, infusion of remifentanil, intermittent iv injetion of atracurium and inhalation of sevoflurane. The patients were mechanically ventilated (VT 8 ml/kg, RR 12 bpm, I:E 1:2, PEEP 0, FiO2 80% ). PET CO2 was maintained at 35-44 mm Hg. Radial artery was cannulated and connected to FloTrac pressure transducer and Vigileo monitor. 6% hydroxyethyl starch 130/0.4 sodium chloride solution 7 ml/kg was infused at a rate of 0,25 ml·kg-1·min-1 at 5 min of haemodynamics stabilization after pericardiotomy (T1). HR, MAP, CVP, systemic vascular resistance (SVR), systemic vascular nesistance index (SVRI), SVV, stroke volume index (SVI) and CI were recorded at T1 and at 10 min after loading dose (T2 ). The change rate of HR(AHR), MAP(AMAP) , CVP(ACVP), SVR(ASVR), SVV(ASVV), SVI(ASVI) and CI(ACI) were calculated. ASVI≥25% was considered effective volume expansion. The ROC curves for HR, MAP, CVP, SVR and SVV in determining the volume expansion efficacy were plotted. The area under the curves and 95 % confidence interval were calculated. Resuits Compared with T1 , CVP, SVI, CO and CI were significantly increased, SVRI and SVV decreased at T2 ( P 〈 0.01 ) . There was no significant difference in MAP and HR between T1 and T2 ( P 〉 0.05) . ASVI was negatively correlated with AHR and ASVR (r = - 0.737, r = - 0.480, P 〈 0.05). ASVI was not correlated with ACVP, AMAP and( P 〉 0.05) .The change in SVI was determined by SVV 8.8% (sensitivity = 52.6%, specificity = 100.0 % ) . The area under the curve for SVV and 95 % confidence interval were 0. 579 (0. 346-0.812) . Conelusion SVV can not be used to accurately monitor the changes in blood volume in patients undergoing off-pump coronary artery bypass grafting.
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 2011年第10期1228-1230,共3页 Chinese Journal of Anesthesiology
关键词 每搏输出量 血管容量 冠状动脉旁路移植术 非体外循环 Stroke volume Vascular capacitance Coronary artery bypass, off-pump
  • 相关文献

参考文献9

  • 1Hawkswoth D L, Kirk P M, Sutton B C, et al. Ainsworth &Bisby' s Dictionary of the Fungi. 8th [ M]. CAB International,1995.
  • 2Bendjelid K, Romand JA. Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care. Intensive Care Med, 2003, 29(3): 352-360.
  • 3张中仪.植物病原真菌学[M].四川:科学技术出版社,1988..
  • 4Cannesson M, Musard H, Desebbe O, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness id mechanically ventilated patients. Anesth Analg, 2009,108(2) :513-517.
  • 5Reuter DA, Goepfert MS, Goresch T, et al. Assessing fluid responsiveness during open chest conditions. Br J Anaesth, 2005,94 (3) : 318-323.
  • 6Wyffels PA, Sergeant P, Wouters PF. The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery. Anaesthesia, 2010, 65(7):704-709.
  • 7Hofer C K, MUller SM, Furrer L, et al. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients un- dergoing off-pump coronary artery" bypass grafting. Chest, 2005,128 (2) :848-854.
  • 8Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology, 1982 , 143 (1):29-36.
  • 9Belloni L, Pisano A, Natale A, et al. Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal eehoehardiography, and pulmonary artery catheter. J Cardiothorae Vase Anesth, 2008, 22 (2) : 243-248.

共引文献1

同被引文献27

  • 1Xiao-Qing Sun Xiao-Bing Fu Rong-Zhan Yi Lü Qun Deng Xiao-Guo Jian Zhi-Yong Sheng Bum Institute, 304~(th)Hospital,Beijing 100037,China Department of General Surgery,Chinese PLA 304 Hospital,Beijing 100037,China.Relationship between plasma D(-)-lactate and intestinal damage after severe injuries in rats[J].World Journal of Gastroenterology,2001,7(4):555-558. 被引量:56
  • 2Boyd JH, Forbes J, Nakada TA, et al. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality [ J]. Crit Care Med, 2011,39 (2) :259 - 265.
  • 3Powner DJ, Miller ER, Levine RL. CVP and PAoP measurements are discordant during fluid therapy after traumatic brain injury[ J]. J In- tensive Care Med,2005,20( 1 ) :28 -33.
  • 4Nduka 00, Parrillo JE. The pathophysiology of septic shock [ J]. Crit Care Nurs Clin North Am,2011,23 ( 1 ) :41 - 66.
  • 5Wyffels PA, Sergeant P, Wouters PF. The value of pulse pressure and stroke volume variation as predictors of fluidresponsiveness during open chest surgery[ J]. Anaesthesia,2010,65 (7) :704 - 709.
  • 6Lahner D, Kabon B, Marschalek C, et al. Evaluation of stroke vol- ume variation obtained by arterial pulse contour analysis to predict flu- id responsiveness intraoperatively [ J ]. Br J Anaesth, 2009,103 ( 3 ) : 346 - 351.
  • 7Lorsomradee S, Lorsomradee S, Cromheecke S, et al. Uncalibrated arterial pulse contour analysis versus continuous thermodilution tech- nique: effects of alterations in arterial waveform [ J]. J Cardiothorac Vasc Anesth ,2007,21 (5) :636 - 643.
  • 8Bowdle T A.Complications of invasive monitoring[J].Anesthesiol Clin North America,2002,20(3):571-588.
  • 9Osman D,Ridel C,Ray P,et al.Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge[J].Crit Care Med,2007,35(1):64-68.
  • 10Li C,Lin F Q,Fu S K,et al.Stroke volume variation for prediction of fluid responsiveness in patients undergoing gastrointestinal surgery[J].Int J Med Sci,2013,10(2):148-155.

引证文献3

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部