摘要 目的探讨能谱CT多期扫描计算的肝动脉碘分数(AIF)与肝CT灌注的肝动脉指数(HAI)的相关性及一致性。方法选取日本大耳白兔15只,行肝CT灌注扫描获得HAI后,以能谱CT多期扫描获取AIF,以相关性分析观察两者之间的相关性,以Bland-Altman图观察两者之间的一致性。结果肝CT灌注扫描的HAI为0.26±0.02,能谱CT扫描计算的AIF为0.25±0.02,两者之间的相关系数为0.979(P<0.05),两者的一致性较好。结论 AIF与HAI相关性、一致性较好,能谱CT扫描可观察肝血流动力学。 Objective To compare the correlation and consistency between hepatic arterial fraction(AIF) calculated from gemstone spectral imaging scan and hepatic arterial index(HAI) measured with perfusion CT.Methods Totally 15 Japanese white rabbits were enrolled.HAI was obtained from perfusion CT,then AIF was got from spectral CT.AIF and HAI were compared with correlation test and Bland-Altman Plot.Results The mean HAI was 0.26±0.02,and the AIF was 0.25±0.02.There was strong positive correlation between HAI and AIF(r=0.979,P0.05),and measurement consistency between the two parameters was high.Conclusion AIF obtained from spectral CT examination correlates strongly with HAI obtained from liver perfusion CT,which can be regarded as a new parameter for evaluating liver hemodynamics.
出处 《中国医学影像技术》 CSCD 北大核心 2011年第12期2381-2384,共4页 Chinese Journal of Medical Imaging Technology
关键词 肝脏 动脉碘分数 肝动脉指数 体层摄影术 X线计算机 灌注成像 宝石能谱成像 Liver Hepatic arterial iodine fraction Hepatic arterial index Tomography X-ray computed Perfusion imaging Gemstone spectral imaging
  • 相关文献

参考文献2

二级参考文献40

  • 1[1]Rademacher G,Stengel D,Siegmann S,et al.Optimization of contrast agent volume for helical CT in the diagnostic assessment of patients with severe and multiple injuries.Comput Assist Tomogr,2002,26(1):113-118.
  • 2[2]Ho LM,Nelson RC,Delong DM.Determining contrast medium dose and rate on basis of lean body weight:does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT? Radiology,2007,243(2):431-437.
  • 3[3]Yanaga Y,Awai K,Nakayama Y,et al.Pancreas:patient body weight-tailored contrast material injection protocol versus fixed dose protocol at dynamic CT.Radiology,2007,245(2):475-482.
  • 4[4]Itoh S,Ikeda M,Satake H,et al.The effect of patient age on contrast enhancement during CT of the pancreatobiliary region.AJR Am J Roentgenol,2006,187(2):505-510.
  • 5[5]Yanaga Y,Awai K,Nakayama Y,et al.Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT.Radiat Med,2007,25(6):278-288.
  • 6[6]Ichikawa T,Erturk SM,Araki T.Multiphasic contrast-enhanced multidetector-row CT of liver:contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients' body-weight-tailored dose of contrast material.Eur J Radiol,2006,58(2):165-176.
  • 7[7]Awai K,Hori S.Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT.Eur Radiol,2003,13(9):2155-2160..
  • 8[9]Suzuki H,Oshima H,Shiraki N,et al.Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta,portal vein and liver at multi-detector row CT:a randomized study.Eur Radiol,2004,14(11):2099-2104.
  • 9[10]Garcia P,Genin G,Bret PM.,et al.Hepatic CT enhancement:effect of the rate and volume of contrast medium injection in an animal model.Abdom Imaging,1999,24(6):597-603.
  • 10[11]Yamashita Y,Komohara Y,Takahashi M,et al.Abdominal helical CT:evaluation of optimal doses of intravenous contrast material-a prospective randomized study.Radiology,2000,216(3):718-723.

共引文献27

同被引文献73

引证文献9

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部