模拟机数字图像形变矫正方法和编程处理实现研究

To study a correction method of distorted digital images generated by simulator and programming
下载PDF
导出
摘要 目的:利用计算机图像处理技术对模拟机扭曲变形的数字图像进行矫正处理研究。方法:利用标准网格模板获取矫正形变参数,然后使用形变参数对实际图像进行形变矫正处理。结果:处理的图像在边缘效果变化明显。整个图像得到较理想的矫正。结论:模拟机直接输出数字图像一定的形变扭曲。利用本方法可以对模拟机图像进行很好的形变矫正,以便保证放射治疗的质量。可以广泛推广使用。 Objective: To use the technology of image processing corrected the distorted digital images generatead by simulator. Methods Getting the distorted parameter from the image of standard grid plate in simulator, and we use these parameter to process the images of patient. Results The edge of images changed significantly. All corrected images had good result. Conclusion The ex- ported digital images from simulator had distorted. We got good correction result with using distorted correction method. In the end, this can improve quality assurance in radiotherapy. This method can be widely adopted.
出处 《医疗装备》 2011年第12期1-3,共3页 Medical Equipment
基金 福建省自然科学基金项目(2010J01137)
关键词 模拟机 图像处理 形变矫正 Simulator Image processing Distorted correction
  • 引文网络
  • 相关文献

参考文献5

二级参考文献19

  • 1黄建军,李平,莫放林.国产模拟定位机影像系统图像存储功能的开发[J].医疗装备,2004,17(12):11-12. 被引量:1
  • 2王瑞玉,刘爱武.数字胃肠X射线机主机控制系统//王瑞玉,刘爱武,主编.医用数字胃肠X射线机原理构造和维修.北京:中国医药科技出版社,2005:8,25-26.
  • 3Yah S,Wang C, Ye M. A method based on moving least squares for XR Ⅱ image distortion correction. Med Phys, 2007,34:4194- 4206.
  • 4Cosby NS,Leszczynski KW. Computer-aided radiation therapy simulation : image intensifier spatial distortion correction for large field of view digital fluoroscopy. Phys Med Biol, 1998,43:2265-2278.
  • 5Wang T M, Liu W Y, Hu L. BPOR: a fluoroscopy- based robot navigating system for distal locking of intramedullary nails[C]//Proceeding of 2004 IEEE/ RSJ International Conference on Intelligent Robots and Systems. Sendal. Japan: IEEE Computer Society, 2004:3321-3326.
  • 6Zhang W Q, Huang X M, Zhang L M. Real-time visualization based on deformed X-ray fluoroscopy [C]//Proeeedings of the First International Multi- Symposiums on Computer and Computational Sciences. Washington DC,USA: IEEE Computer Society, 2006 : 792-795.
  • 7Liu R R, Rudin S, Bednarek D R. Super-global distortion correction for a rotational C-arm X-ray image intensifier[J]. Medical Physics, 1999, 26(9): 1802- 1810.
  • 8Fahrig R, Moreau M, Holdsworth D W. Three-dimensional computed tomographie reconstruction using a C-arm mounted XRII: correction of image intensifier distortion [J]. Medical Physics, 1997, 24 (7):1097-1106.
  • 9Cerveri P, Forlani C. Distortion correction for X-ray image intensifiers: local unwarping polynomials and RBF neural networks [J]. Medical Physics, 2002, 29(8): 1759-1771.
  • 10Glasbey C A, Horgan G W, Gibson G J, et al. Fish shape analysis using landmarks [J]. Biometrical Journal, 1995, 37: 481-485.

共引文献31

;
使用帮助 返回顶部