期刊文献+

缓变狭窄幅度径向振荡血管内血流动力学 被引量:8

HEMODYNAMICS ON PULSATILE FLOW THROUGH A VESSLE WITH MILD STENOSIS AMPLITUDE OSCILLAING RADIALLY
下载PDF
导出
摘要 本文研究缓变狭窄幅度径向振荡血管内血液脉动流。求解线化的Navier-St.okes血流方程和管壁方程,得出速度剖面和管壁切应力。结果表明狭窄参数的变化对流动有很大影响。在狭窄区内,速度变化和狭窄程度及狭窄幅度振荡频率的耦合作用有关。当狭窄幅度振荡频率接近血流基频时,血液速度变化较大,并且狭窄区最大壁切应力达到峰值。 In this paper, pulsative flow through a vessel with mild stenosis amplitude oscillating radically wasinvestigated. Velocities and wall shear stress were obtained by solving linearlzed N-S equations andWall equation. Results showed stenosis parameters had effect on blood flow. Variations in velocitywas sever and maximum wall shear stress reached peak value at stenosis amplitude oscillatingfrequency near the flow basic frequency.
出处 《医用生物力学》 EI CAS CSCD 1999年第4期202-207,共6页 Journal of Medical Biomechanics
关键词 缓交狭窄血管 狭窄幅度径向振荡 血流动力学 vessel with mild stenosis, stenosis amplitude oscillating radially, Hemodynamics
  • 相关文献

参考文献3

  • 1吕岚,医用生物力学,1999年,14卷,143页
  • 2Lee J S,J Appl Mech,1970年,29卷,9页
  • 3Yong D F,J Engnd Ind trans ASME,1968年,90卷,248页

同被引文献42

  • 1李义凯,陈建华,邱桂春.脊柱推拿时咔哒声响的测量技术分析与设计[J].第一军医大学学报,2005,25(4):419-422. 被引量:7
  • 2许世雄,计琳,王庆伟.中医滚法推拿对血液流动影响的数值研究[J].应用数学和力学,2005,26(6):694-700. 被引量:29
  • 3陈文君,许世雄.推拿颈动脉窦降低体动脉压数学模型研究[J].上海生物医学工程,2006,27(2):70-73. 被引量:4
  • 4Shixiong X, Lin J,Yongtian C, et al. Numerical Investigation of Effect of Rolling Manipulation of Traditional Chinese Medical Massage on blood Flow [ A]. Applied Mathematics and Mechanics [ M] (will be published)
  • 5Lin J, Low HT, Chew YT,et al. Flow through a blood vessel with stenosis moving axially [ C ]. 2003 Summer Bioengineering Conference, June 25 - 29, Sonesta Beach Resort in Key Biscayne, Florida.
  • 6Berger SA,Jou LD. Flow in stenotic Vessels [J]. Annu Rev Fluid Mech,2002,32:347 -382.
  • 7Shixiong X,Juntao Y, Xinwen Z,et al. Pulsatile blood flow through a cylindrical tube with a mild stenosis axially[ c ]. 9th International Conferene on Biomedical Engineering December 3 -6 1997 ,Singapore.
  • 8Chakravarty S, Datta A, Mandal PK. Analysis of nonlinear blood flow in a stenosed flexible artery [ J ]. Int J Engng Sci, 1995,33(12): 1821 - 1837.
  • 9Yong DF. Effect of a time -dependent stenosis on flow through a tube [ J]. J England Ind Trans ASME, 1986,90:248.
  • 10Chakravarty S, Datta A, Mandal PK. Effect of body acceleration on unsteady flow of blood past a time - dependent artery stenosis [ J ]. Mathl Comput Modelling, 1996,24 (2): 57 - 74.

引证文献8

二级引证文献113

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部