期刊文献+

医院二次供水的微生物监测及预防感染对策 被引量:6

Monitoring of microorganism in secondary water supply and countermeasures for infection prevention
原文传递
导出
摘要 目的研究医院的二次供水中微生物的数量及构成。方法随机取二次供水及相应自来水样本各15份,定量涂抹培养于营养琼脂上,35℃孵育24、48h观察结果。结果自来水中微生物含量为0~32CFU/ml,平均3.1CFU/ml,二次供水中微生物含量为0~3600CFU/ml,平均604.3CFU/ml,两者比较,差异有统计学意义(t=2.421,P<0.05)。结论医院的二次供水中可含有大量微生物,主要是非发酵菌;具有引发医院感染的潜在危险性,应当引起广大医院感染管理工作者的足够重视。 BJECTIVE To study the quantity and composition of microorganism living in hospital secondary water supply. METHODS The quantity of random secondary water supply samples was 15,as well as the corresponding tap water at the same time.Immediately,they were quantitatively smeared on nutrient mediums and cultured under 35 ℃ for 24 hours and 48 hours. RESULTS The concentration of microorganism detected in tap water was 0-32 CFU/ml and the average was 3.1 CFU/ml,while the quantity in secondary supply was 0-3600 CFU/ml and the average was 604.3 CFU/ml.The discrepancy was obvious. CONCLUSIONS There may be plenty of microorganism especially non-fermentative bacteria in hospital secondary water supply,which can result in the happening of hospital infection.And more attention should be paid to this problem.
出处 《中华医院感染学杂志》 CAS CSCD 北大核心 2011年第24期5231-5232,共2页 Chinese Journal of Nosocomiology
关键词 二次供水 微生物监测 医院感染 消毒 管理 Secondary water supply Microorganism determination Hospital infection Disinfection Management
  • 相关文献

参考文献3

二级参考文献19

  • 1Levin AS. Nosocomial legionellosis: prevention and management[J]. Expert Rev Anti Infect Ther, 2009,7 (1) : 57-68.
  • 2Bartram J, Chartier Y, Lee JV, et al. Legionella and the prevention of legionellosis [M]. Printed in India: WHO Press, 2007 : 14-15.
  • 3Farhat M, Trouilhe MC, Briand E, et al. Development of a pilot-scale 1 for Legionella elimination in biofilm in hot water network: heat shock treatment evaluation[J]. J Appl Micro biol. Published Online:28. 2009.
  • 4van derKooij D, Veenendaal HR, Scheffer WJ. Biofilmformation and multiplication of Legionella in a modelwarmwater system with pipes of copper, stainless steel and crosslinked polyethylene[J]. Water Res,2005,39:2789-2798.
  • 5Liu Z, Lin YE, Stout JE, etal. Effect of flow regimes on the presence of Legionella within the biofilm of a model plumbing system[J]. J Appl Microbiol,2006,101:437-442.
  • 6Saby S, Vidal A, Suty H. Resistance of Legionella to disinfection in hot water distribution systems[J]. Water Sei Technol,2005,52(8):15-28.
  • 7Bartram J,Chartier Y,Lee JV,etal. Legionella and the prevention of legionellosis[M]. 1st ed. Printed in India: WHO Press, 2007 : 15.
  • 8Taylor M, Ross K, Bentham R. Legionella, Protozoa, and Biofilms:Interactions within Complex Microbial Systems[J].Microb Ecol, 2009,58 (3) : 538-547.
  • 9Declerck P,Ollevier F. Detection of Legionella in Various Sample Types Using Whole-Cell Fluorescent In Situ Hybridization. Methods in Molecular Biology Diagnostic Bacteriology Protocols[M]. 2nd ed. Belgium: Humana Press,2006:175-183.
  • 10Litaker RW. Life cycle of the heterotrophic dinoflagellate pfiesteria piscicida (dinophyceae)[J].J Phycol, 2002,38: 442- 463.