期刊文献+

HFC-161混合物替代R502的理论研究 被引量:2

Theoretical Study on HFC-161 Mixture as an Alternative Refrigerant to R502
下载PDF
导出
摘要 提出一种新型制冷剂HFC-161/125/143a(质量百分比10/45/45)用于替代制冷剂R502。新制冷剂环境性能良好,ODP值为0,GWP值为3466,GWP值小于R502及其常用替代制冷剂R404A和R507。采用Refprop软件计算了HFC-161混合物的基本热物理性质,以及低温工况和变工况下的理论循环性能,并与制冷剂R502、R404A、R507的相关数据进行对比。结果表明:新制冷剂的运行压力、压比、COP值、单位容积制冷量与R502相当,温度滑移小于R502常用替代物R404A,是一种性能优良的制冷剂R502的替代物。 A ternary HFC-161 mixture (HFC-161/125/143a with mass ratio 10/45/45) was proposed as an alternative refrigerant to R502. Theoretical results indicated that it is an environmentally friendly refrigerant with zero ODP (ozone depletion potential) and a GWP (global warming potential) value of 3466, which is lower than that of R502, R404A and R507. The thermophysical properties and theoretical cycle performance of HFC-161 mixture under low temperature working conditions and varying working conditions were calculated and compared with R502, R404A and R507 by software Refprop. The calculation results indicated that the operating pressure, pressure ratio, COP and cooling capacity per unit volume of HFC-161 mixture are equivalent to those of R502, and its temperature glide is smaller than that of R404A. Therefore, HFC-161 mixture can be used as a potential alternative refrigerant to R502.
出处 《制冷学报》 CAS CSCD 北大核心 2011年第6期59-63,共5页 Journal of Refrigeration
关键词 工程热物理 替代制冷剂 HFC-161 R502 环保 Engineering thermophysics Pyrology Alternative refrigerant HFC-161 R502 Environmentally friendly
  • 相关文献

参考文献6

  • 1Calm J M, Hourahan G C. Refrigerant data summary[J]. Engineered Systems, 2001, 18 (11) : 74-88.
  • 2郭智凯,陈光明,宣永梅,等.一种替代R502的环保型制冷剂:中国,200310108660.3[P].2003.
  • 3杨昭,吴曦,尹海蛟,刘焕卫.低温室效应HCFCs替代物性能分析[J].制冷学报,2011,32(1):1-6. 被引量:35
  • 4National Institute of Science and Technology (NINI) Standard reference database. Thermodynamic and transport properties of refrigerants and refrigerant mixtures [DB]. Version 7.0. 2002.
  • 5Huber M L, Ely J F. A predictive extended corresponding states model for pure and mixed refrigerants including an equation of state for R134a [J]. International Journal of Refrigeration, 1994, 17 (1) : 18-31.
  • 6Yaws C L. Chemical Properties Handbook [M]. Beijing: Mc Graw-Hill Book Co., 1999.

二级参考文献13

  • 1张朝晖.中国工商制冷空调领域HCFC淘汰计划制定工作进展计划[C]//第四届中国制冷空调行业信息大会,2009.
  • 2史琳,朱明善.家用/商用空调R32作为R22替代品的再分析[C]//第四届中国制冷空调行业信息大会,2009.
  • 3M.Mohanraj, S.Jayaraj. Environment friendly alternatives to halogenated refrigerants[J]. International Journal of Greenhouse Gas Control, 2009, 3 (1) :108-119.
  • 4D Styles, P O Brien. Measuring the environment performance of IPPC industry: I. Devising a quantitative science-based and policy-weighted environment emissions index[J]. Environmental Science & Policy, 2009,12 (3) :226-242.
  • 5Florian Zink, Jeffrey S Vipperman. Environmental motivation to switch to thermoacoustic refrigeration [J]. Applied Thermal Engineering, 2010,30 (2) :119-126.
  • 6K.Wang, M. Eisele, Y. Hwang, et al. Review of secondary loop refrigeration systems[J]. International Journal of Refrigeration, 2010, 33 (2) :212-234.
  • 7M. Fatouh, A. Talaat. Performance assessment of a direct expansion air conditioner working with R407C as an R22 alternative [J]. Applied Thermal Engineering, 2010, 30(2-3) :127-133.
  • 8J Fernandez Seara, J U Francisco.Vapor condensation of R22 retrofit substitutes R417A, R422A and R422D on CuNi turbo C tubes[J]. International Journal of Refrigeraion, 2010, 23 (1) :148-157.
  • 9P Laj, J Klausen, M Blide, et al. Measuring atmospheric composition change[J]. Atmospheric Environment, 2009, 43 (33) :5351-5414.
  • 10Barbara H.Minor, David Herrmann, Robert Gravell. Flammability Characteristics of HFO-1234yf[J]. Process Safety Progress, 2010, 29 (2) :150-154.

共引文献34

同被引文献16

  • 1宁静红,马一太,李敏霞.R290/CO_2自然工质低温复叠式制冷循环理论分析[J].天津大学学报,2006,39(4):449-453. 被引量:29
  • 2Kilicarslan A, Hosoz M. Energy and irreversibility analy- sis of a cascade refrigeration system for various refriger- ant couples [ J ]. Energy Conversion and Management, 2010,51 (12) :2947 - 2954.
  • 3Kruse H H Riissmann. The natural fluid nitrous oxide-- an option as substitute for low temperature synthetic re- frigerants [ J ]. International Journal of Refrigeration, 2006.29( 5 ) :799 - 806.
  • 4Souvik Bhattacharyya, Mukhopadhyay S, Kumar A, et al. Optimization of a CO2 - C3Hscascade system for refrig- eration and heating[J]. International Journal of Refrige- ration, 2005,28 : 1284 - 1292.
  • 5Souvik Bhattacharyya, Anirban Garai, Jahar Sarkar. Thermodynamic analysis and optimization of a novel N20 - CO2 cascade system for refrigeration and heating [ J ]. International Journal of Refrigeration, 2009,32 : 1077 - 1084.
  • 6Getu H M P K Bansal. Thermodynamic analysis of an R744- 11717 cascade refiigeration system [ J ]. Interna- tional Journal of Refrigeration, 2008,31 ( 1 ) :45 -54.
  • 7Antonio Messineo. 11744 - 11717 Cascade Refrigeration System: Performance Evaluation compared with a HFC Two - Stage System[ J ]. Energy Procedia, 2012,14:56 -65.
  • 8Rezayan O A Behbahaninia. Thermoeconomic optimiza- tion and exergy analysis of COJNH3 cascade refrigera- tion systems [ J ]. Energy, 2011,36 ( 2 ) :888 - 895.
  • 9Kaushik S C,Kumar P,Jain S. Performance evaluation of irreversible cascaded refrigeration and heat pump cy-cles[ J]. Energy Conversion and Management, 2002, 43 ( 17 ) :2405 - 2424.
  • 10Calm J M, Hourahan G C. Refrigerant Data Summary [J]. Engineered Systems, 2001,18( 11 ) :74 -88.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部