为解决无机房电梯控制柜的通风与散热问题,分析了控制柜的布置特点和设置要求,计算了控制柜散热通风需求量,并结合工程实例探讨了解决方案和给出了相关建议,为无机房电梯控制柜的通风与散热提供了参考.
In order to solve the problems of ventilation and heat dissipation in control cabinet of non-room elevator,we have analyzed layout characteristics of the control cabinet and related requirements,and calculated the cooling and ventilation demands.Solutions are given with the concrete examples.These suggestions can be used as reference for this type of control cabinet.
出处
《甘肃科学学报》
2011年第4期130-132,共3页
Journal of Gansu Sciences
关键词
无机房电梯
控制柜
散热
通风
non-room elevator
control cabinet
cooling