摘要
本文针对空分装置工艺冷却器在分子筛切换时液位波动冷却水进入分子筛事故的现象进行阐述,分析造成事故的原因,提出预防措施。
The accident happened process air cooler liquid level fluctuation,cooling water got into molsieve adsorber when it changed was described Carried out and preventive measured proposed.
出处
《内蒙古石油化工》
CAS
2011年第18期51-52,共2页
Inner Mongolia Petrochemical Industry
关键词
工艺冷却器
液位波动
原因
预防措施
Process air cooler
Liquid level Fluctuation
Cause
Precaution