期刊文献+

数字断层融合检查对肺内孤立性结节筛检的初步应用 被引量:4

Preliminary Study of Chest Digital Tomosynthesis for the Screening of Solitary Pulmonary Nodules
原文传递
导出
摘要 目的探讨胸部数字断层融合(digital tomosynthesis,DTS)检查对肺内孤立性结节(solitary pulmonary nod-ules,SPN)的检出能力。资料与方法肺部可疑结节患者及恶性肿瘤随访患者共87例,均行常规数字化胸部平片和胸部DTS检查,以多层CT作为参照,观察分析DTS和胸部平片对SPN的检出结果,分别统计敏感性、特异性、准确性、阳性预测值、阴性预测值,并进行χ2检验,比较两者差异性。结果 87例经CT发现54个结节,胸部平片检出24个,假阳性8个,假阴性30个。DTS检出49个,假阳性1个,假阴性5个。胸部平片和DTS对SPN的敏感性、特异性、准确性、阳性预测值、阴性预测值分别为44.4%、75.8%、56.3%、75%、45.5%和90.7%、96.9%、92%、98%、86.1%,DTS与胸部平片对SPN检查的各项指标差异具有统计学意义(P<0.05)。结论 DTS是普通放射学检查的有力补充,能够提高普通放射学对SPN的诊断能力,可作为影像检查链中的重要环节,在肺部肿瘤高危人群低剂量筛检、复诊方面可以替代常规胸片检查。 Objective To discuss the value of digital tomosynthesis in detection of solitary pulmonary nodules.Materials and Methods Eighty seven patients suspected of pulmonary nodules and cancer underwent chest X ray radiography,digital tomosynthesis and CT examination in follow up.Imaging data were transferred to post processing workstation and were reviewed by 2 radiologists in a double blind method.The sensitivity,specificity,accuracy,positive and negative predictive values of chest X-ray radiography and digital tomosynthesis for detection of solitary pulmonary nodules were calculated according to the CT results.Chi square test was used for the detection index of radiography and digital tomosynthesis examination.Results Fifty four nodules were detected by CT examination in 87 patients.24 nodules were detected by X-ray radiography and 30 nodules were negative,8 patients were false positive.40 nodules were detected by digital tomosynthesis,and only 5 nodules were negative,1 patient was false positive.The sensitivity,specificity,accuracy,positive and negative predictive values of the X-ray radiography were 44.4%,75.8%,56.3%,75%,45.5% respectively,and those of the digital tomosynthesis were 90.7%,96.9%,92%,98%,86.1%(P0.05 respectively).Conclusion Digital tomosynthesis as a high sensitivity for detection of solitary pulmonary nodules compared with X-ray radiography,could be an excellent supplementary technique of X-ray radiography.Digital tomosynthesis would be well suited as a low-dose screening technique substitute for X ray radiography.
出处 《临床放射学杂志》 CSCD 北大核心 2011年第12期1768-1771,共4页 Journal of Clinical Radiology
基金 四川省卫生厅科研课题(编号:110640)
关键词 断层融合术 放射摄影术 体层摄影术 X线计算机 孤立性肺结节 Tomosynthesis Radiography Tomography X-ray computed Solitary pulmonary nodules
  • 相关文献

参考文献14

  • 1Dobbins JT 3rd, Godfrey DJ. Digital X-ray tomosynthesis: current state of the art and clinical potential. Physics in Medicine and Biology ,2003,48:65.
  • 2McAdams HP, Samei E, Dobbins JT 3rd, et al. Recent advances in chest radiography. Radiology, 2006,241 : 663.
  • 3Dobbins JT 3rd, MeAdams kiP, Godfrey D J, et al. Digital tomosynthesis of the chest. Thorac Imaging,2008,23:86.
  • 4Vikgren J, Zaehrisson S, Svalkvist, at el. Comparison of chest tomo-synthesis and chest radiography for detection of pulmonary nodules : human observer study of clinical cases. Radiology ,2008,249 : 1034.
  • 5Eun YK, Myung JC, Ho YL, et al. Pulmonary mycobacterial disease : diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography. Radiology, 2010,257 : 269.
  • 6孙志远,苏宏,赵艳娥,鞠兵,常双会,胡秋菊,卢光明.数字化体层融合在肺结节探查中的初步应用[J].中华放射学杂志,2010,44(1):33-36. 被引量:27
  • 7Angelica S, Lars GM, Magnus B. Monte carlo simulation dosimetry of chest tomosynthesis. Radiation Protection Dosimetry,2010,139 : 144.
  • 8刘彬,白玫.64层螺旋CT检查中患者受照剂量的研究[J].中华放射学杂志,2008,42(10):1050-1052. 被引量:23
  • 9Morin RL, Gerber TC, McCollough CH. Radiation dose in computed tomography of the heart. Circulation,2003,107:917.
  • 10李真林,杨志刚,余建群,陈宪,郭应昆.多层螺旋CT肺部低剂量与常规剂量检查的放射剂量评估[J].临床放射学杂志,2004,23(2):113-115. 被引量:42

二级参考文献61

  • 1Colang JE, Killion JB, Vano E. Patient dose from CT: a literature review. Radiol Technol,2007,79 : 17-26.
  • 2Brenner D J, Hall EJ. Computed tomography:an increasing source of radiation exposure. N Engl J Med,2007 ,357 :2277-2284.
  • 3Brody AS, Frush DP, Huda W, et al. Radiation risk to children from computed tomography. Pediatrics ,2007,120:677-682.
  • 4Campbell J, Kalra MK, Rizzo S, et al. Scanning beyond anatomic limits of the thorax in chest CT: findings, radiation dose, and automatic tube current modulation. AJR,2005,185 : 1525-1530.
  • 5Donnelly LF, Emery KH, Brody AS,et al. Minimizing radiation dose for pediatric body application of single-detector helical CT: strategies at a large Children's Hospital. AJR, 2001, 176: 303 -306.
  • 6Nyman U, Ahl TL, Kristiansson M, et al. Patient-circumference- adapted dose regulation in body computed tomography, a practical and flexible formula. Acta Radiol, 2005,46:396-406.
  • 7Sigal-Clinquabre AB, Hennequin R, Abada HT, et al. Low- kilovohage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Rdiology,2004,231: 169-174.
  • 8Thomas CK, Muhlenbruch G, Wildberger JE, et al. Coronary artery calcium scoring with muhislice computed tomography: in vitro assessment of a low tube voltage protocol. Invest Radiol, 2006, 41:668-673.
  • 9Heneghan JP, McGuire KA, Leder RA, et al. Helical CT for nephrolithiasis and ureterolithiasis: comparison of conventional and reduced radiation : dose techniques. Radiology, 2003,229 :575-580.
  • 10Haaga JR, Miraldi F, Maclntyre W, et al. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology, 1981, 138:449-454.

共引文献230

同被引文献40

  • 1顾晓林,龚沈初,沈云霞.35例胸部隐匿部位的病变数字化X线摄影分析[J].中国医学影像学杂志,2007,15(1):56-58. 被引量:5
  • 2Dobbins JT 3rd, Godfrey DJ. Digital x-ray tomosynthesis:current state of the art and clinical potential. Phys Med Biol,2003,48(19): R65-106.
  • 3Dobbins JT 3rd, Mcadams HP, Godfrey DJ, et al. Digitaltomosynthesis of the chest. J Thorac Imaging, 2008,23(2): 86-92.
  • 4Vikgren J,Zachrisson S, Svalkvist A, et al. Comparisonof chest tomosynthesis and chest radiography for detection ofpulmonary nodules: human observer study of clinical cases.Radiology, 2008, 249(3): 1034-1041.
  • 5Svalkvist A, Mansson LG, BSth M. Monte Carlo simulations ofthe dosimetry of chest tomosynthesis. Radiat Prot Dosimetry,2010,139(1-3): 144-152.
  • 6Kim EY, Chung MJ, Lee HY, et al. Pulmonary mycobacterialdisease: diagnostic performance of low-dose digitaltomosynthesis as compared with chest radiography. Radiology,2010, 257(1): 269-277.
  • 7Wolbarst AB, William R. Evolving and experimental technologiesin medical imaging. Radiology, 2006, 238(1): 16-39.
  • 8Asplund S,Johnsson AA,Vikgren J, et al. Learning aspectsand potential pitfalls regarding detection of pulmonary nodulesin chest tomosynthesis and proposed related quality criteria.Acta Radiol, 2011, 52(5): 503-512.
  • 9Dobbins JT 3rd, McA dams HP . Chest tomosynthes is: technical principles and clinical update [ J ]. EurJ Radiol, 2009,72 ( 2 ) :244 -251.
  • 10Dobbins JT 3rd,Godfrey DJ. Digital x-ray tomosynthesis:current state of the art and clinical potential[J].{H}Physics in Medicine and Biology,2003,(19):R65-106.

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部