摘要 论述了IEC 61850信息建模技术和状态监测IED建模步骤,分析了报告服务,并针对变压器状态监测的特点,合理扩展和使用了IEC 61850标准中的逻辑节点和数据,对实际变压器状态监测IED进行了建模,用变电站配置描述语言(SCL)对该模型进行了描述,该模型描述文件通过了按标准句法(Schema模式)对其进行的测试。 This paper discusses IEC61850 information modeling techniques and modeling steps of condition-monitoring IED and analyzes the reporting service. In the light of the characteristics of transformer condition monitoring, logical nodes and datas in the IEC61850 standard are rationally developed and applied, and the model for actual intelligent eleetronic device (IED) of transformer condition monitoring is established and described in substation configuration description language (SCL). The configuration file of this model has passed the test done with standard syntax (Schema mode).
出处 《华东电力》 北大核心 2011年第12期2012-2016,共5页 East China Electric Power
基金 上海市科委科技攻关资助项目(10dz1203000)~~
关键词 电力变压器 状态监测 IEC 61850模型 变电站配置描述语言 transformer condition monitoring IEC61850 model substation configuration description language