摘要 分析滤光镜对物体成像特性的影响,确定其所引起的镜头畸变类型,并针对该类型采用除式模型(DM)来校正镜头畸变.利用除式模型特殊的结构形式将标定过程转化为线性求解过程,避免了传统标定方法采用多项式校正模型(PM)进行非线性优化搜索,提高了标定效率,保证了标定参数的稳定性.标定实验和实物配准实验表明,采用除式模型校正滤光镜所引起的镜头畸变,其测量精度要优于多项式模型和针孔模型. The effect of filter on imaging feature was analyzed and the type of lens distortion was determined.The division model(DM) was used to correct the lens distortion,and its special constructional features was used to transform the calibration process to linear solution process,which avoiding nonlinear optimization searching process with polynomial model(PM) of the traditional camera calibration method.The proposed algorithm can improve the efficiency and the stability.Experiments of calibration and registration show that the measuring accuracy in DM is superior to that in PM and Pinhole.
出处 《大连海事大学学报》 CAS CSCD 北大核心 2011年第4期67-70,共4页 Journal of Dalian Maritime University
基金 国家自然科学基金资助项目(50575029)
关键词 线结构光 摄像机标定 滤光镜 径向畸变 除式模型 line structured-light camera calibration filter radial distortion division model
  • 相关文献

参考文献6

二级参考文献22

  • 1贺俊吉,张广军,杨宪铭.基于交比不变性的镜头畸变参数标定方法[J].仪器仪表学报,2004,25(5):597-599. 被引量:53
  • 2郭鸿,邓烽,张靖,李成群,员超,李柏林.基于图像处理的激光扫描三维尺寸测量技术的研究[J].工具技术,2004,38(11):75-78. 被引量:1
  • 3尤红建,张世强.组合CCD图像和稀疏激光测距数据的建筑物三维信息提取[J].光学精密工程,2006,14(2):297-302. 被引量:15
  • 4Roger Y. Tsai. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE. Journal of Robotics and Automation, 1987, RA-3(4):323-344.
  • 5Janne H. Geometric camera calibration using circular control points. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(10):1066-1077.
  • 6Zhengyou Zhang. A flexible new technique for camera calibration. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(11):1330-1334.
  • 7Alan M. Mclvor. Nonlinear calibration of a laser stripe profiler. Optical Engineering, 2002,41(1):205-212.
  • 8Juyang Weng. Camera calibration with distortion models and accuracy evaluation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 1992, 14(10):965-980.
  • 9K. Vijayan Asari. A new approach for nonlinear distortion correction in endoscopic images based on least squares estimation. IEEE Transactions on Medical Imaging, 1999,18(4):345-354.
  • 10Warren E. Smith. Correction of distottion in endoscope images. IEEE Transactions on Medical Imaging, 1992, 11(1):117-122.

共引文献126

同被引文献23

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部