对某高层建筑火灾后的现场调查内容、检测方法和结果进行介绍,通过分析检测结果,综合评定了结构的受损情况,并制定了结构修复加固设计方案。目前,该建筑经过修复加固后已经投入使用,加固后的建筑完全满足使用要求,可为日后高层建筑火灾工程的检测鉴定和加固设计提供借鉴和参考。
The content of local investigation, test approach and result for a high rise building after fire disaster was introduced. Based on the analysis of tested result, assessed synthetically the damage of the structure, constituted the project of structure strengthening design. At the present, the building have been used after repair and strengthening and the building satisfied the demand entirely, and it provides the referents for the later test, appraise and strengthening design of high rise building after fire disaster.