1Liu X,Zhao X,Huang J,et al.Comparison of 3D free-breathing coronary MR angiography and 64-MDCT angiography for detection of coronary stenosis in patients with high calcium scores[J].AJR Am J Roentgenol,2007,189(6):1326-1332.
2Liu X,Bi X,Huang J,et al.Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T:comparison with steady-state free precession technique at 1.5 T[J].Invest Radiol,2008,43(9):663-668.
3Budoff MJ,Cohen MC,Garcia MJ,et al.ACCF/AHA clinical competence statement on cardiac imaging with computed tomography and magnetic resonance:a report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training[J].J Am Coll Cardiol,2005,46(2):383-402.
4Yang Q,Li KC,Bi XM,et al.3T contrast-enhanced whole heart coronary MRA using 32-channel cardiac coils for the detection of coronary artery disease[J].J Cardiovasc Magnet Reson,2009,11 Suppl 1:S1-5.
5Plein S,Jones TR,Ridgway JP,et al.Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating[J].AJR Am J Roentgenol,2003,180(2):505-512.
9Pouleur AC,le Polain de Waroux JB,Kefer J,et al.Direct comparison of whole-heart navigator-gated magnetic resonance coronary angiography and 40-and 64-slice multidetector row computed tomography to detect the coronary artery stenosis in patients scheduled for conventional coronary angiography[J].Circ Cardiovasc Imaging,2008,1(2):114-121.
10Muthupillai R,Smink J,Hong S,et al.SENSE or k-MAG to accelerate free breathing navigator-guided coronary MR angiography[J].AJR Am J Roentgenol,2006,186(6):1669-1675.
4Moody AR, Murphy RE, Morgan PS, et al. Characterization of complicated carotid plaque with magnetic resonance direct thrombus imaging in patients with cerebral isehemia. Circulation, 2003(107) : 3047-3049.
5Viereck J, Ruberg FL, Qiao Y, et al. MRI of Atherothrombosis associated with plaque rupture. Arteriosclerosis, Thrombosis, and Vascular Biology, 2005,25 (1) : 240-245.
6Saito K, Saito M, Komatu S, et al. Real-time four dimensional imaging of the heart with multi-detector row CT. Radiographics, 2003,23 (3) : 686-688.
7Flohr TG, Stierstorfer K, Ulzheimer S, et al. Image reconstruction and image quality evaluationf or a 64-slice CT scanner with zflying focal spot. Med Phys, 2005,32(8) :2536- 2547.
8Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual source CT coronary angiography: first experience in a high pre test probability population without heart rate control. Eur Radiol, 2006, 16(12) : 2739-2747.
9Achenbach S, Ropers D, Kuettner A, et al. Contrast enhanced coronary artery visualization by dual-source computed tomography initial experience. Eur Radiol, 2006,57(3):331 -335.